Key result
Inertial load near 8+ Gz halts blood flow to the upper body and brain.
Why the study?
The study investigated the use of numerical methods for modelling the effects of inertial load on the human cardiovascular system.
Does inertial load up to 8+Gz alter blood flow velocities and mass flow in the human aortic arch compared to standard earth gravity?
Does inertial load up to 8+Gz alter blood flow velocities and mass flow in the human aortic arch compared to standard earth gravity?
Fluid-structure interaction modeling demonstrates that inertial loads up to 8+Gz significantly reduce cerebral blood flow, ceasing entirely near 8+Gz, providing a computational basis for G-force induced cerebral hypoxia.
No takes yet. Share an insight, caveat, or question.
May explain G-LOC at high inertial loads; leaves open human aortic flow validation.
Presented is an investigation into the use of numerical methods for modelling the effects of inertial load on the human cardiovascular system. An anatomically correct geometry was developed based on three-dimensional computed tomography (CT) data and independent meshes were created for the solid and fluid regimes. These domains were simulated using independent solvers and subsequently coupled using an intermediate data transfer alogrithm. At the inlet of the arch, a pulsatile velocity boundary condition was enforced replicating the cardiac cycle. Time invariant, resistive boundary conditions were used at all outlets and a linear isotropic constitutive model was used for tissue response. Verification was conducted by comparing simulation results at standard earth gravity (9.81 m/s²) with published values for velocity, mass flow rate, deformation, and qualitative flow behaviour. The presented fluid-structure interaction (FSI) model shows strong agreement with accepted normal values. Inertial load was then applied along the longitudinal axis of the arch in multiples of standard gravity to a maximum of 8+Gz. This load increased arch flow velocities, and reduced mass flow in the ascending brachiocephalic and carotid arteries. Blood flow from the arch to the upper body and brain ceased near 8+Gz. Although the presented results are preliminary, the feasibility of such an analysis has been successfully demonstrated.
Jonathan M Zalger (2021) studied Inertial load effects on the human cardiovascular system. Inertial load (up to 8+ Gz) vs. Standard earth gravity (1 Gz) was evaluated on Blood flow velocity and mass flow in the aortic arch. Inertial load up to 8+ Gz increased aortic arch flow velocities and reduced mass flow, causing blood flow to the upper body and brain to cease near 8+ Gz.