Key result
Simulated inertial loads near 8+Gz halt blood flow to the upper body and brain.
Why the study?
The study investigated the use of numerical methods for modelling the effects of inertial load on the human cardiovascular system.
Does inertial load up to 8+Gz alter blood flow velocities and mass flow in a computational model of the human aortic arch?
Does inertial load up to 8+Gz alter blood flow velocities and mass flow in a computational model of the human aortic arch?
Fluid-structure interaction modeling successfully demonstrates that high inertial loads (up to 8+Gz) significantly alter aortic arch hemodynamics, leading to cessation of blood flow to the brain.
Model predicts cerebral flow cessation near 8 Gz; leaves open relevance to human G-LOC without in vivo validation.
Presented is an investigation into the use of numerical methods for modelling the effects of inertial load on the human cardiovascular system. An anatomically correct geometry was developed based on three-dimensional computed tomography (CT) data and independent meshes were created for the solid and fluid regimes. These domains were simulated using independent solvers and subsequently coupled using an intermediate data transfer alogrithm. At the inlet of the arch, a pulsatile velocity boundary condition was enforced replicating the cardiac cycle. Time invariant, resistive boundary conditions were used at all outlets and a linear isotropic constitutive model was used for tissue response. Verification was conducted by comparing simulation results at standard earth gravity (9.81 m/s²) with published values for velocity, mass flow rate, deformation, and qualitative flow behaviour. The presented fluid-structure interaction (FSI) model shows strong agreement with accepted normal values. Inertial load was then applied along the longitudinal axis of the arch in multiples of standard gravity to a maximum of 8+Gz. This load increased arch flow velocities, and reduced mass flow in the ascending brachiocephalic and carotid arteries. Blood flow from the arch to the upper body and brain ceased near 8+Gz. Although the presented results are preliminary, the feasibility of such an analysis has been successfully demonstrated.
No takes yet. Share an insight, caveat, or question.
Jonathan M Zalger (2021) studied Effects of inertial load on the human cardiovascular system. Inertial load (up to 8+Gz) vs. Standard earth gravity (9.81 m/s²) was evaluated on Velocity, mass flow rate, deformation, and qualitative flow behaviour. Application of inertial load up to 8+Gz to a fluid-structure interaction model of the human aortic arch increased flow velocities and caused blood flow to the upper body and brain to cease near 8+Gz.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: