Key result
Maximum true deceleration >110 m/s2 predicts ~364% higher atrial arrhythmia recurrence post-PVI, outperforming conduction velocity.
Why the study?
The role of conduction deceleration in identifying abnormal left atrial substrate and arrhythmia recurrence following AF ablation had not been investigated.
Does left atrial deceleration outperform regional conduction velocity in predicting arrhythmia recurrence following atrial fibrillation ablation?
Cohort (n=86)
No
Does left atrial deceleration outperform regional conduction velocity in predicting arrhythmia recurrence following atrial fibrillation ablation?
Effect estimate: HR 4.64 (95% CI 1.66-13.0)
p-value: p=0.003
Left atrial deceleration may outperform regional conduction velocity in predicting arrhythmia recurrence following AF ablation, potentially guiding future substrate-based ablation trials.
May stratify post-PVI recurrence risk; leaves open whether deceleration mapping should guide substrate ablation trials.
Background: ) is associated with atrial arrhythmia (AA) recurrence following atrial fibrillation (AF) ablation; however, the role of conduction deceleration has not been investigated. Objective: in identifying abnormal left atrial (LA) substrate and AA recurrence in patients undergoing de novo pulmonary vein isolation (PVI). Methods: ) were quantified. TD was calculated as the largest continuous decline in CV along the propagating wavefront divided by the change in activation time. AF patients underwent PVI and AA recurrence was assessed during 12-month follow-up. Results: ) only colocalized with LVA sites in a minority of LA regions (range 13%-44%) and were absent from control subjects. Conclusion: . This may guide future trials focusing on improving success from substrate-based AF ablation.
No takes yet. Share an insight, caveat, or question.
Massin et al. (2025) conducted a cohort in Atrial fibrillation (n=86). Maximum true deceleration (TDmax > 110 m/s2) vs. Slowest regional conduction velocity (CVmin < 0.2 m/s) was evaluated on Atrial arrhythmia recurrence >30 seconds at 1 year (HR 4.64, 95% CI 1.66-13.0, p=0.003). Maximum true deceleration greater than 110 m/s2 significantly predicted atrial arrhythmia recurrence following pulmonary vein isolation (HR 4.64), outperforming regional conduction velocity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: