Key result
Post-TAVI CT identifies THV thrombosis in ~4% of mostly asymptomatic patients with normal echocardiograms.
Why the study?
Does multidetector computed tomography (MDCT) detect early transcatheter heart valve thrombosis in patients after TAVI?
Observational (n=140)
Does multidetector computed tomography (MDCT) detect early transcatheter heart valve thrombosis in patients after TAVI?
MDCT is a valuable tool for diagnosing early subclinical transcatheter heart valve thrombosis post-TAVI, revealing it may be more common than previously anticipated.
MDCT may reveal subclinical THV thrombosis missed by echocardiography post-TAVI; leaves open its clinical significance and management.
BACKGROUND: Early stent valve thrombosis after transcatheter aortic valve implantation (TAVI) is a rare complication, which is diagnosed based on the appearance of clinical symptoms of heart failure and echocardiographic findings. After TAVI, transthoracic echocardiography is performed to assess transcatheter heart valve (THV) function. However, preliminary reports indicate the potential additive clinical value of multidetector computed tomography (MDCT) for the diagnosis of THV thrombosis. We sought to determine the value of MDCT for the diagnosis of THV thrombosis and the frequency of this complication after balloon-expandable TAVI. METHODS AND RESULTS: MDCT was performed in 140 patients within 1 to 3 months after TAVI with the Edwards Sapien XT THV to assess the presence of THV thrombosis and THV stent geometry. Post-TAVI MDCT identified THV thrombosis in 5 patients (4%). Of note, 4 of these patients were asymptomatic and had a normal transthoracic echocardiographic examination without signs of thrombus formation or flow obstruction. In patients with THV thrombosis, a left ventricular ejection fraction of <35% was present in 3 (60%), whereas 2 (40%) did not receive standard post-TAVI dual-antiplatelet therapy. Neither THV underexpansion nor THV noncircularity was detected in patients with THV thrombosis. CONCLUSIONS: Post-TAVI MDCT is a valuable tool for the diagnosis of THV thrombosis, and this complication seems to be more common than previously anticipated. Larger studies are required to identify specific risk factors of THV thrombosis.
No takes yet. Share an insight, caveat, or question.
Leetmaa et al. (2015) conducted an observational in Post-TAVI (n=140). Multidetector computed tomography (MDCT) was evaluated on Presence of transcatheter heart valve (THV) thrombosis. Post-TAVI multidetector computed tomography identified transcatheter heart valve thrombosis in 4% of patients, most of whom were asymptomatic with normal echocardiographic findings.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: