Key result
Leadless pacemakers appear safe after prior conventional pacing with 0 periprocedural complications or infections.
Why the study?
Leadless pacemakers are increasingly used in patients after a previously implanted conventional pacing system, but efficacy and safety in this setting required evaluation.
Is leadless pacemaker implantation safe and effective in patients with a prior conventional pacing system compared to de novo implantation?
Cohort (n=257)
Yes
Is leadless pacemaker implantation safe and effective in patients with a prior conventional pacing system compared to de novo implantation?
Leadless pacemaker implantation is safe and effective in patients with a prior conventional pacing system, with no increased risk of complications compared to de novo implantation.
Answers are grounded in this paper and cite their sources.
Supports leadless upgrades after conventional systems in select patients; hypothesis-generating and should not yet change practice.
BackgroundLeadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often leadless pacemaker (LP) implantation represents de novo procedure, whereas in an increasing number of patients LP is used after a previously implanted conventional pacing system (CPS).MethodsRetrospective analysis of the efficacy and safety of LP implantation in context of previously implanted CPS from two large Swiss centres.Results257 consecutive patients undergoing LP implantation were included and divided into two groups: group one of 233 patients who did not have a history of CPS, and group two of 24 patients, with in situ CPS. In group two, 20 (83%) required transvenous lead extraction due to infection, malfunction or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, while in the remaining 11 cases time window between the two procedures was present (median 11.5 days, range 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the two groups (mean 12.5±9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 femoral bleedings and 1 intra-abdominal bleeding) in the entire cohort within 30-day period. No complications occurred in the group with a previous device. There were no infections registered, even when complete extraction of infected CPS was performed prior to LP implantation.ConclusionsImplantation of a LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients. Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often leadless pacemaker (LP) implantation represents de novo procedure, whereas in an increasing number of patients LP is used after a previously implanted conventional pacing system (CPS). Retrospective analysis of the efficacy and safety of LP implantation in context of previously implanted CPS from two large Swiss centres. 257 consecutive patients undergoing LP implantation were included and divided into two groups: group one of 233 patients who did not have a history of CPS, and group two of 24 patients, with in situ CPS. In group two, 20 (83%) required transvenous lead extraction due to infection, malfunction or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, while in the remaining 11 cases time window between the two procedures was present (median 11.5 days, range 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the two groups (mean 12.5±9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 femoral bleedings and 1 intra-abdominal bleeding) in the entire cohort within 30-day period. No complications occurred in the group with a previous device. There were no infections registered, even when complete extraction of infected CPS was performed prior to LP implantation. Implantation of a LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.
No takes yet. Share an insight, caveat, or question.
Jelisejevas et al. (2023) conducted a cohort in Patients requiring leadless pacemaker implantation (n=257). Leadless pacemaker implantation in patients with a prior conventional pacing system vs. Leadless pacemaker implantation without a history of conventional pacing system was evaluated on Efficacy and safety (electrical device parameters and periprocedural complications). Leadless pacemaker implantation in patients with a prior conventional pacing system was effective and safe, with 0 periprocedural complications or infections observed in this group.
Synapse has enriched 10 related papers. Consider them for comparative context: