Key result
Cardiac device infections are linked to ~35% mortality despite appropriate treatment.
Cardiac device infections are severe complications requiring complete device removal and antibiotic therapy, carrying a mortality rate of up to 35%.
The increasing number of implantation procedures of implantable cardiac electronic devices (ICEDs) leads to a substantial growth of a cohort of patients in whom complications of such a therapy occur. Infective complications are among the most severe ones, as they are often associated with poor prognosis. Depending on the criteria applied, the incidence of cardiac device infection (CDI) is estimated at 0.5-2.2%. Many risk factors of CDIs have been identified, among which the most important are numerous previous cardiac electrotherapy procedures and their complexity, and the lack of perioperative antibiotic prophylaxis. Appropriate diagnosis of a suspected CDI is of utmost importance, as well as the correct classification of the infection, which leads to adequate treatment. Management of a CDI should include complete removal of the implanted device. Additionally, empirical and then targeted antibiotic therapy should be instituted. The prognosis of CDI may, nonetheless, be unfavorable. Despite appropriate treatment, the total mortality rate of such complication is estimated to be as high as 35%.
No takes yet. Share an insight, caveat, or question.
Sławiński et al. (2018) conducted a review in Cardiac device infection (CDI). Cardiac device infections have an estimated incidence of 0.5-2.2% and are associated with a total mortality rate as high as 35% despite appropriate treatment.