Key result
Lead-dependent infective endocarditis is linked to ~7-fold higher rates of fever than pocket infections.
Why the study?
Cardiovascular implantable electronic device infections cause serious clinical problems, with lead-dependent infective endocarditis (LDIE) considered the worst. This study aimed to analyze the clinical manifestations, etiology, and microbiological profile of these infections and evaluate the role of echocardiography in diagnosing LDIE.
Observational (n=767)
No
In patients with cardiac device infections, lead-dependent infective endocarditis is characterized by higher inflammatory markers and fever, with transesophageal echocardiography being the preferred imaging modality for detecting vegetations.
Answers are grounded in this paper and cite their sources.
Fever may distinguish lead-dependent endocarditis from pocket infection in device recipients; leaves open prospective validation of TEE for vegetation detection.
Introduction: Cardiovascular implantable electronic device infections (CIEDIs) cause a lot of serious clinical problems among which lead dependent infective endocarditis (LDIE) is considered to be the worst. Background:The background of the study was to analyze the parameters of clinical manifestations, determine the etiology and microbiological profile of the infections as well as evaluate the role of echocardiography in diagnosing LDIE.Methods: Retrospective examinations were carried out in Reference Clinical Cardiology Centre in Lublin, Poland.The study group comprised 767 patients who between 2009 and 2014 underwent transvenous lead extraction (TLE) for infective and non-infective reasons.Results: The study group comprised 382 patients with infective complications and 385 without infection.CIEDI group included 30.1% LDIE patients, 38.48% pocket infection patients (PI) and 31.41%mixed LDIE and PI patients.Fever was most frequently reported in LDIE patients.Significantly more LDIE patients were found to suffer from concomitant infections.LDIE group comprised significantly more patients with hs-CRP>50 mg/dL.Analysis of microbiological data showed that the most common cause of the infective complications were Staphylococcus epidermis and Staphylococcus aureus.Echocardiography examination revealed the presence of vegetation in 78.26% of LDIE patients in TEE and in 63.48% in TTE.Conclusions: Fever and concomitant infections predominated in the clinical picture of LDIE.Hs-CRP value proved to be essential for diagnostic procedures.TEE examination proved to be more effective in revealing vegetation than TTE.The most common cause of infective complications was S. epidermidis and S. aureus which points out to the endogenic source of infections.
No takes yet. Share an insight, caveat, or question.
Montewka et al. (2016) conducted an observational in Cardiovascular implantable electronic device infections (CIEDIs) and lead-dependent infective endocarditis (LDIE) (n=767). Lead-dependent infective endocarditis (LDIE) vs. Pocket infection (PI) or mixed LDIE and PI was evaluated on Presence of fever (>38°C) in LDIE vs. pocket infection (p=0.0001). Lead-dependent infective endocarditis presented with more frequent fever than pocket infection, with vegetations detected in 78.26% by TEE vs. 63.48% by TTE.
Synapse has enriched 10 related papers. Consider them for comparative context: