Key result
Simultaneous high-output pacing during RF ablation is linked to ~90% acute procedural success for VT.
Why the study?
Scar homogenization with additional testing for electrical inexcitability are known catheter ablation endpoints, but achieving both can be time consuming.
Does simultaneous high-output pacing during radiofrequency ablation achieve acute procedural success in patients with scar-related ventricular tachycardia?
Observational (n=10)
Does simultaneous high-output pacing during radiofrequency ablation achieve acute procedural success in patients with scar-related ventricular tachycardia?
Simultaneous high-output pacing during radiofrequency ablation is a feasible and safe strategy to achieve scar inexcitability and noninducibility in patients with scar-related VT.
May support high-output pacing during scar-related VT ablation; hypothesis-generating and should not yet change practice.
Objectives To describe an expedited strategy of simultaneous high‐output pacing during radiofrequency ablation to achieve scar homogenization and electrical inexcitability as an approach for substrate ablation for scar‐related ventricular tachycardia (VT). Background Scar homogenization with additional testing for electrical inexcitability is known endpoints for catheter ablation, but achieving both can be time consuming. We describe a strategy of simultaneous pacing during radiofrequency ablation to expedite this approach. Methods and results Ten patients (age 74 ± 6 years; all men, (LV) ejection fraction of 33% ± 8%, ischemic cardiomyopathy, 9; VT storm, 7) underwent scar homogenization with electrical inexcitability to pacing (10 mA, 9 ms pulse width), as well as noninducibility of any VT as an acute procedural endpoint. Thirty‐four VTs were inducible in 10 patients with a total of 1127 ablation lesions applied. Median ablation lesions per patient were 97 (interquartile range [IQR] 25‐75 71‐151), and the total ablation time was 49 minutes (IQR 25‐75 45‐56 minutes) with average duration per lesion of 32.2 seconds (IQR 25‐75 25.8‐37.8 seconds). Average power was 33 W (IQR 25‐75 32‐38 W), average contact force was 13 g (IQR 25‐75 11.9‐14.6 g) with a median impedance drop of 9.6 Ω/lesion (IQR 25‐75 8.1‐10.0 Ω). There were no ventricular fibrillation episodes using this strategy. The median procedure time was 246 minutes (IQR 25‐75 214‐293 minutes). Acute procedural success was seen in nine patients with 97% of VTs noninducible. Conclusion Simultaneous ablation with high output pacing to achieve scar inexcitability, when combined with scar homogenization and noninducibility of any VT may be an expeditious, safe, and effective technique for catheter ablation.
No takes yet. Share an insight, caveat, or question.
Anderson et al. (2020) conducted an observational in Scar-related ventricular tachycardia (n=10). Simultaneous high-output pacing during radiofrequency ablation was evaluated on Acute procedural success (noninducibility of any VT). Simultaneous high-output pacing during radiofrequency ablation achieved acute procedural success in 9 of 10 patients, with 97% of ventricular tachycardias rendered noninducible.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: