Key result
Score Map-guided PVC ablation shows an 86% success rate with low complications.
Why the study?
Ablation of premature ventricular complexes remains challenging in routine electrophysiology, and the study aimed to analyze the exclusive use of the Score Map software pace-mapping technique and its procedural success.
Does exclusive use of pace-mapping software for catheter ablation improve procedural success in symptomatic patients with premature ventricular complexes?
Observational (n=47)
No
Does exclusive use of pace-mapping software for catheter ablation improve procedural success in symptomatic patients with premature ventricular complexes?
Exclusive use of pace-mapping software for PVC ablation is feasible and associated with high acute success, particularly when the Score Map is >95%.
May support Score Map-guided PVC ablation in selected patients; hypothesis-generating and requires RCTs before practice change.
Introduction/Objective: Ablation of premature ventricular complexes a challenge in routine electrophysiology because results, depend on factors such as location, tools and technologies used. Aim of study was analyze exclusive use of pace-mapping technique with module of Score Map Software of Ensite Velocity/Precision and compare with success procedure, 7- and 30-days post-ablation. Methods/Results: Retrospectively analyzed 50 procedures in 47 symptomatic patients between January 2018 and February 2020. Ablation with irrigated tip catheter, power 40Watts, pump flow 30ml/min. Mapping with Duodecapolar in 40(80%) and HDGrid catheter in 10(20%). Female was 25 (53.19%), mean age 53.5years (19-78), hypertension 27 (57.45%), 7 (14.91%) coronary disease, 4 (8.51%) myocarditis, 2 (4.26%) Diabetes and 2 (4.26%) patients with an implanted defibrillator. Mean ejection fraction 63.17%. Average radiofrequency time was 580.58 seconds and mean XRay time 7.74min. Median SM was 93.92% and only 8 (16%) ablations were considered unsuccessful due to maintenance of extrasystoles or do not show a marked reduction on PVC at the end of the procedure. At 7- and 30-days follow up 9 (18%) and 7 (14%) patients had unsuccessful ablation. All patients had a Score <95%, underwent ablation with conscious sedation, majority female, most PVCs located in left ventricle and had more extensive ablation. Conclusion: Score Map is useful as exclusive technique for ablation of premature ventricular complexes with very good acute success and low complications. Score Map more than 95% had high success. Failure is related to conscious sedation, female gender, left ventricle ablation and longer radiofrequency time.
No takes yet. Share an insight, caveat, or question.
Fabrício Vassallo (2020) conducted an observational in Symptomatic premature ventricular complexes (n=47). Catheter ablation guided exclusively by pace-mapping software (Score Map™) was evaluated on Successful ablation at 30-days follow-up. Catheter ablation of premature ventricular complexes guided exclusively by Score Map™ software achieved an 86% success rate at 30 days follow-up with a low complication rate.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: