Key result
Distal-to-proximal delay ≥15 ms accurately predicts successful PVC ablation sites.
Why the study?
Mapping the origin of premature ventricular contractions can be challenging during catheter ablation, prompting evaluation of a new electrophysiological criterion, the distal-to-proximal delay, to localize optimal ablation sites.
Does distal-to-proximal delay accurately localize the optimal site for ablation of premature ventricular contractions in patients with symptomatic PVCs?
Observational
Blinded assessors
Does distal-to-proximal delay accurately localize the optimal site for ablation of premature ventricular contractions in patients with symptomatic PVCs?
A distal-to-proximal delay ≥15 milliseconds is a highly accurate and simple electrophysiological criterion for localizing successful ablation sites for premature ventricular contractions.
May aid PVC ablation site selection; extends mapping criteria but leaves open need for prospective validation.
INTRODUCTION: Ablation of premature ventricular contractions (PVCs) has emerged as a safe and effective treatment in patients experiencing a high PVCs burden. Mapping of PVCs origin may sometimes be challenging. We sought to evaluate the accuracy of a new electrophysiological criterion, the distal-to-proximal (DP) delay, at localizing the optimal site for ablation of ventricular ectopic foci. METHODS AND RESULTS: Consecutive patients with ablation attempts of symptomatic PVCs were included. Prematurity and DP delay-that is, the time duration between the onset of ablation catheter distal bipolar electrogram and the onset of proximal bipolar electrogram-were measured at successful and unsuccessful ablation sites by three blinded experienced electrophysiologists. Mean DP delay at effective ablation sites (N = 30) was significantly higher than at ineffective sites ( N = 55) (23 ± 9 vs 11 ± 8 milliseconds; P < 0.0001). DP delay had good-to-excellent interrater reliability. A DP delay greater than or equal to 15 milliseconds had the highest accuracy at predicting a successful ablation site (sensitivity 0.97, the area under receiver operating characteristic curve 0.87; P < 0.0001). CONCLUSION: DP delay is an additional, simple, and effective electrophysiological parameter to accurately localize PVCs foci.
No takes yet. Share an insight, caveat, or question.
Clémenty et al. (2018) conducted an observational in Symptomatic premature ventricular contractions (PVCs). Distal-to-proximal (DP) delay measurement vs. Ineffective ablation sites was evaluated on Mean DP delay at effective versus ineffective ablation sites (AUC 0.87, p=<0.0001). A distal-to-proximal delay ≥15 milliseconds accurately predicted successful ablation sites for premature ventricular contractions (sensitivity 0.97, AUC 0.87; P<0.0001).