Key result
Willem AI detects ATTR-CM from standard 12-lead ECGs with 0.88 AUC.
Why the study?
ATTR-CM is frequently underdiagnosed, and diagnostic delays limit treatment efficacy; AI applied to standard 12-lead ECGs may improve early detection.
Does the Willem AI platform applied to standard 12-lead ECGs accurately detect transthyretin amyloid cardiomyopathy in adults evaluated for the disease?
Observational (n=2,901)
No
Does the Willem AI platform applied to standard 12-lead ECGs accurately detect transthyretin amyloid cardiomyopathy in adults evaluated for the disease?
An AI model applied to routine 12-lead ECGs demonstrated high diagnostic accuracy for detecting transthyretin amyloid cardiomyopathy, including in early-stage disease and high-risk clinical scenarios.
Answers are grounded in this paper and cite their sources.
May support ECG-based ATTR-CM screening in evaluated adults; leaves open prospective validation before clinical use.
BACKGROUND: Transthyretin amyloid cardiomyopathy (ATTR-CM) is a frequently underdiagnosed disease in which delay in diagnosis limits the efficacy of treatments. Artificial intelligence (AI) applied to standard 12-lead electrocardiograms (ECGs) is promising and may help improve ATTR-CM early detection. OBJECTIVES: The goals of this study were to extend the Willem AI cloud platform for ATTR-CM detection from 12-lead ECGs and to evaluate its performance across relevant patient subgroups, including early-stage disease. METHODS: This was a single-center retrospective study of adults evaluated for ATTR-CM. Controls had negative 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy and clinical assessment to exclude ATTR-CM. After quality control, 20,754 ECGs from 2901 individuals [585 patients with ATTR-CM (20.2%) and 2316 controls (79.8%)] were used. Patients were split into training/validation and test data sets, with stratification by amyloidosis status, sex, and age groups. A time-slicing convolutional neural network generated ECG probabilities aggregated by max-pooling. Threshold selection targeted 90% sensitivity in validation. RESULTS: In the test cohort, Willem AI achieved an area under the receiver operating characteristic curve (AUC) of 0.88 (95% confidence interval, 0.85-0.91), a sensitivity of 80.7%, and a specificity of 78.5%. Performance was similar for hereditary transthyretin amyloidosis or hereditary ATTR (ATTRv; AUC, 0.91) and wild-type transthyretin amyloidosis or wild type ATTR (ATTRwt; AUC, 0.88) and remained informative in early presentations (asymptomatic sensitivity 68.4%; New York Heart Association class I 73.9%). Willem AI achieved high accuracy in "red-flag" scenarios: carpal tunnel syndrome (AUC, 0.92), lumbar spinal stenosis (AUC, 0.92), and polyneuropathy (AUC, 0.91). CONCLUSION: This work expands Willem AI capabilities, enabling automated ATTR-CM detection from routine 12-lead ECGs in a real-world referral population. The Willem AI model may support informed clinical management and scalable triage to trigger confirmatory testing and accelerate diagnosis.
No takes yet. Share an insight, caveat, or question.
González-López et al. (2026) conducted an observational in Transthyretin amyloid cardiomyopathy (ATTR-CM) (n=2,901). Willem AI platform (12-lead ECG analysis) vs. Clinical assessment and scintigraphy (reference standard) was evaluated on Area under the receiver operating characteristic curve (AUC) for ATTR-CM detection (AUC 0.88, 95% CI 0.85-0.91). The Willem AI platform detected ATTR-CM from standard 12-lead ECGs with an AUC of 0.88, achieving 80.7% sensitivity and 78.5% specificity in the test cohort.