Key result
High resolution ultrasound with 2D speckle tracking strongly correlated with MRI for measuring radial (R=0.91) and circumferential (R=0.84) strain in post-MI mice.
Why the study?
Does high resolution ultrasound with speckle tracking accurately quantify regional cardiac contractile dysfunction compared to MRI in mice post-MI?
Does high resolution ultrasound with speckle tracking accurately quantify regional cardiac contractile dysfunction compared to MRI in mice post-MI?
High resolution ultrasound with speckle tracking provides accurate quantification of regional cardiac contractile dysfunction in mice post-MI, correlating highly with MRI.
Supports ultrasound speckle tracking for strain in post-MI mouse models; leaves open clinical translation pending human validation.
High resolution 30 MHz ultrasound imaging was performed on the left ventricles (LV) of C57B1/6 mice post myocardial infarction (MI). Normal (no MI) C57B1/6 mice were examined as control experiments. Ultrasound imaging was performed at 5-7 short axis slices and 4-5 long axis slices at 1 mm intervals that encompass the LV. Myocardial tissue displacement vectors were measured using a 2D ultrasonic speckle tracking algorithm with sub-pixel resolution. The pixel block window size was approximately 0.4 mm times 0.4 mm and the search region was 0.6 mm times 0.6 mm. The extent of contractile dysfunction and cardiac dyssynchrony were revealed in post-MI mouse LVs by regional myocardial displacement and strain analyses. Strain analyses from the mid-ventricular short axis based upon the ultrasound images were compared to those obtained using MRI, and high levels of correlation were obtained (R = 0.91 and R = 0.84 for radial and circumferential strain, respectively). Displacement and strain analyses were conducted on multiple short axis and long axis slices, and 3D displacement vectors were determined at the lines of intersection by summing the vector components derived from each of the orthogonal slices
No takes yet. Share an insight, caveat, or question.
Li et al. (2006) studied Myocardial Infarction (in mice). High resolution 30 MHz ultrasound imaging with 2D ultrasonic speckle tracking vs. MRI (for validation) was evaluated on Correlation of radial and circumferential strain between ultrasound and MRI (R = 0.91 (radial), R = 0.84 (circumferential)). High resolution ultrasound with 2D speckle tracking strongly correlated with MRI for measuring radial (R=0.91) and circumferential (R=0.84) strain in post-MI mice.