Key result
The use of balloon-expandable valves (OR 3.014) and lower body mass index (OR 0.884) independently predicted a decrease in platelet count of ≥50% after transcatheter aortic valve implantation.
Why the study?
Thrombocytopenia is common after TAVI and is associated with mortality and major complications, but the underlying mechanisms remain unclear.
What are the predictors of a ≥ 50% decrease in platelet count after transfemoral TAVI in Japanese patients?
Observational (n=131)
No
What are the predictors of a ≥ 50% decrease in platelet count after transfemoral TAVI in Japanese patients?
Low BMI and the use of balloon-expandable valves are independent predictors of significant short-term thrombocytopenia following transfemoral TAVI in Japanese patients.
OBJECTIVE: Thrombocytopenia is common after transcatheter aortic valve implantation (TAVI) and is associated with mortality and major complications, although the underlying mechanisms are unclear. This retrospective single-center study aimed to identify factors associated with the decrease in platelet count (DPC) after TAVI in Japanese patients. Patients with severe aortic valve stenosis who underwent transfemoral TAVI between March 2014 and August 2019 were grouped according to DPC values of < 50% or ≥ 50% (DPC = 100% × [baseline platelet count-nadir platelet count]/[baseline platelet count]). Multivariable logistic regression analysis was performed to identify factors associated with a DPC of ≥ 50%. RESULTS: Among the 131 patients who underwent transfemoral TAVI, 74 patients (56%) had a DPC of ≥ 50%, and 57 patients (44%) had a DPC of < 50%. Significant risk factors for a DPC of ≥ 50% were older age, lower body mass index (BMI), and use of balloon-expandable valves (BEV). The multivariable analysis revealed that a DPC of ≥ 50% was independently predicted by low BMI (adjusted odds ratio: 0.884, 95% confidence interval: 0.785-0.997; P = 0.039) and BEV use (adjusted odds ratio: 3.014, 95% confidence interval: 1.003-9.056; P = 0.045). Platelet count monitoring after TAVI, especially when using BEV devices, is essential for Japanese patients with low BMI.
No takes yet. Share an insight, caveat, or question.
Yamada et al. (2020) conducted an observational in Severe aortic valve stenosis (n=131). Balloon-expandable valves vs. Self-expanding valves was evaluated on Decrease in platelet count of ≥ 50% (OR 3.014, 95% CI 1.003-9.056, p=0.045). The use of balloon-expandable valves (OR 3.014) and lower body mass index (OR 0.884) independently predicted a decrease in platelet count of ≥50% after transcatheter aortic valve implantation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: