Why the study?
Does intracardiac echocardiography (ICE) accurately guide balloon sizing and predict acute ablation success compared to angiography in patients undergoing cryoballoon pulmonary vein isolation for paroxysmal atrial fibrillation?
Population
22 patients undergoing pulmonary vein cryoballoon ablation for drug refractory paroxysmal atrial fibrillation.
Comparison
Intracardiac echocardiography to guide… vs PV angiography.
Design
Cohort
Authors
Loading...
ICE total PV occlusion may predict acute cryoballoon PVI success; hypothesis-generating and requires prospective trials versus angiography.
Does intracardiac echocardiography (ICE) accurately guide balloon sizing and predict acute ablation success compared to angiography in patients undergoing cryoballoon pulmonary vein isolation for paroxysmal atrial fibrillation?
Intracardiac echocardiography is a feasible nonfluoroscopic imaging technique that can accurately guide balloon sizing and predict acute success during cryoballoon pulmonary vein isolation.
Nölker et al. (2010) studied this question.