PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 9, 2009IEEE Transactions on Biomedical Engineering44 citations

Nonlinear Stochastic Regularization to Characterize Tissue Residue Function in Bolus-Tracking MRI: Assessment and Comparison With SVD, Block-Circulant SVD, and Tikhonov

View Full Paper
FZFrancesca ZanderigoABAlessandra BertoldoGPGianluigi Pillonetto

Key Points

Key points are not available for this paper at this time.

Abstract

An accurate characterization of tissue residue function R(t) in bolus-tracking magnetic resonance imaging is of crucial importance to quantify cerebral hemodynamics. R(t) estimation requires to solve a deconvolution problem. The most popular deconvolution method is singular value decomposition (SVD). However, SVD is known to bear some limitations, e.g., R(t) profiles exhibit nonphysiological oscillations and take on negative values. In addition, SVD estimates are biased in presence of bolus delay and dispersion. Recently, other deconvolution methods have been proposed, in particular block-circulant SVD (cSVD) and Tikhonov regularization (TIKH). Here we propose a new method based on nonlinear stochastic regularization (NSR). NSR is tested on simulated data and compared with SVD, cSVD, and TIKH in presence and absence of bolus dispersion. A clinical case in one patient has also been considered. NSR is shown to perform better than SVD, cSVD, and TIKH in reconstructing both the peak and the residue function, in particular when bolus dispersion is considered. In addition, differently from SVD, cSVD, and TIKH, NSR always provides positive and smooth R(t).

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zanderigo et al. (2009) studied this question.

synapsesocial.com/papers/6a0f2ef84045c7e590426fcbhttps://doi.org/10.1109/tbme.2009.2013820
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Deconvolution of dynamic contrast‐enhanced MRI data by linear inversion: Choice of the regularization parameter2004 · 37 citations
  2. 2Cerebral blood flow measurement by dynamic contrast MRI using singular value decomposition with an adaptive threshold1999 · 15 citations
  3. 3Nonstationary Iterated Tikhonov Regularization1998 · 183 citations
  4. 4Equations for Measuring Blood Flow by External Monitoring of Radioisotopes1965 · 790 citations
  5. 5The Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems1993 · 3,128 citations