Key result
Index RF and cryoballoon ablation yield similar 3-year arrhythmia-free survival after repeat paroxysmal AF ablation.
Why the study?
The study sought to evaluate the impact of the energy source used during index ablation on long-term clinical outcomes following repeat ablation of AF.
Does the use of cryoballoon versus radiofrequency current for index ablation impact long-term freedom from atrial fibrillation after a repeat radiofrequency ablation in patients with paroxysmal AF?
Cohort (n=195)
Does the use of cryoballoon versus radiofrequency current for index ablation impact long-term freedom from atrial fibrillation after a repeat radiofrequency ablation in patients with paroxysmal AF?
Absolute Event Rate: 48% vs 47%
p-value: p=0.78
The choice of energy source (radiofrequency vs cryoballoon) for index pulmonary vein isolation does not affect long-term arrhythmia-free survival following a repeat radiofrequency ablation.
Aims The current study sought to assess the impact of the utilized energy source during index ablation on long‐term clinical outcomes after repeat ablation of atrial fibrillation (AF). Index ablation procedures were either performed using radiofrequency current (RFC) (RFC group) or cryoballoon (CB) ablation (CB group). Repeat ablation was performed by the use of RFC. Methods A total of 195 patients (138 RFC group; 57 CB group) with paroxysmal AF were included. All patients had a recurrence of AF following the index ablation procedure. Freedom from AF was estimated with the Kaplan‐Meier method. Results After a 3 years follow‐up, the estimated arrhythmia‐free survival did not differ between the two groups (RFC group 48% vs CB group 47%, P = .78). During index ablation, procedure times were significantly shorter in the CB group (95 [80, 140] vs 140 [115, 164] minutes, P ≤ .001), whereas fluoroscopy times (16 [11; 22] vs 19 [14; 25] minutes, P = .003), the dose area product (1862 [1203; 2922] vs 3148 [1756; 5888] cGycm 2 , P ≤ .001) and the amount of contrast dye (92 ± 32 vs 123 ± 33 mL, P ≤ .001) were significantly lower in the RFC group. During repeat ablation, procedure times were significantly shorter in patients being initially treated with RFC (115 [85; 145] vs 125 [105; 150] minutes, P = .007). There was a trend towards a higher pulmonary vein reconnection rate in the RFC group without meeting statistical significance ( P = .074). Conclusions In patients with repeat ablation of AF, index RFC or CB ablation are equally effective in terms of freedom from AF. Although CB ablation results in shorter index procedures times, durations of repeat ablation are significantly longer.
No takes yet. Share an insight, caveat, or question.
Inaba et al. (2020) conducted a cohort in Paroxysmal atrial fibrillation (n=195). Radiofrequency current (RFC) ablation vs. Cryoballoon (CB) ablation was evaluated on Freedom from atrial fibrillation (arrhythmia-free survival) (p=0.78). Index radiofrequency current and cryoballoon ablation yielded similar 3-year arrhythmia-free survival (48% vs 47%, P=0.78) following repeat ablation for recurrent paroxysmal atrial fibrillation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: