Key result
Exercise test parameters at ICD implantation did not predict device-delivered shocks, but a VE/VCO2 slope >35 and appropriate shocks were independently associated with adverse clinical events.
Why the study?
It was unknown whether primary prevention ICD patients who receive a first device-delivered electric shock have a poor prognosis even at the time of ICD implantation.
Does the exercise test performed at the time of ICD implantation predict the occurrence of device-delivered electric shock or adverse clinical events in patients with ischemic or dilated cardiomyopathy?
Cohort (n=55)
Does the exercise test performed at the time of ICD implantation predict the occurrence of device-delivered electric shock or adverse clinical events in patients with ischemic or dilated cardiomyopathy?
Exercise testing at the time of primary prevention ICD implantation does not predict future appropriate shocks, but both abnormal exercise parameters and receiving a shock independently indicate a poor prognosis.
Answers are grounded in this paper and cite their sources.
Exercise testing at ICD implant should not guide shock prediction; leaves open whether VE/VCO2 slope identifies higher-risk patients for closer monitoring.
(1) Background: Receiving the first internal electric shock is a turning point for patients with an implantable cardioverter defibrillator (ICD) for primary prevention. However, no study has investigated whether patients who receive a first device-delivered electric shock have a poor prognosis even at the time of ICD implantation. (2) Methods: We retrospectively identified 55 patients with ischemic (n = 31) or dilated (n = 24) cardiomyopathy who underwent ICD implantation for primary prevention with exercise test at the time of implantation. We recorded baseline characteristics, exercise test parameters, and clinical events. (3) Results: After a median follow-up of 5 years, we observed an association between an appropriate device-delivered electric shock, the occurrence of death or heart transplant, and the occurrence of the composite endpoint. There was also a significant relation between a VE/VCO2 slope >35 and the occurrence of the composite endpoint. Conversely, there was no significant association between negative outcomes on the exercise test and the occurrence of a device-delivered electric shock. (4) Conclusions: The exercise test performed at the time of ICD implantation do not predict the occurrence of device-delivered electric shock. The exercise test and the first electric shock are two independent markers of poor prognosis.
No takes yet. Share an insight, caveat, or question.
Théry et al. (2023) conducted a cohort in Ischemic or dilated cardiomyopathy with ICD for primary prevention (n=55). Exercise test parameters and device-delivered electric shock was evaluated on Device-delivered electric shock, death or heart transplant, and composite endpoint. Exercise test parameters at ICD implantation did not predict device-delivered shocks, but a VE/VCO2 slope >35 and appropriate shocks were independently associated with adverse clinical events.