Why the study?
VDD pacemakers offer more physiological pacing than VVI devices by preserving atrial sensing, but their long-term performance in elderly patients with AVB required evaluation.
Does VDD pacemaker implantation provide reliable long-term physiological pacing in elderly patients with atrioventricular block and normal sinus rhythm?
Does VDD pacemaker implantation provide reliable long-term physiological pacing in elderly patients with atrioventricular block and normal sinus rhythm?
VDD pacing is a reliable long-term modality in elderly patients with AVB and normal sinus rhythm, with over 90% maintaining VDD mode at 3 years.
High VDD preservation supports durability in selected elderly AVB patients; leaves open RCTs versus DDD pacing.
BACKGROUND: In elderly patients, single chamber pacing may be considered. For sinus rhythm patients, VDD pacemaker (PM), by preserving atrial sensing, is a more physiological mode than VVI devices. This study aims to evaluate the long-term performance of VDD PM in elderly patients with atrioventricular block (AVB). METHODS: We conducted a retrospective, observational study of 200 elderly patients (≥75 years) with AVB and normal sinus rhythm who consecutively implanted VDD PM between 2016 and 2018. Baseline clinical characteristics were analyzed, complications related to pacemaker implantation were assessed and a 3-years follow-up (FUP) was made. RESULTS: Mean age was 84 ± 5 years. After 3-years FUP, 90.5% (n = 181) of the patients preserved their original VDD mode. Only 19 patients (9.5%) switched to VVIR mode, 5.5% (n = 11) due to P-wave undersensing and 4% (n = 8) due to permanent AF. Those patients had a less amplitude of sensed P wave at baseline [median value of 1.30 (IQR 0.99-2.0) versus 0.97 (IQR 0.38-1.68), p = 0.04]. One third of the patients died during the FUP, 89% (n = 58) from non-cardiovascular causes. All-cause, CV, and non-CV mortality did not relate with atrial sensing loss during FUP (p = 0.58, p = 0.38 and p = 0.80, respectively). However, atrial sensing loss during FUP was associated with de novo atrial fibrillation (12.7% vs. 31.6%, p = 0.038). CONCLUSION: VDD pacing is a reliable pacing modality in elderly patients even in long-term. The majority of VDD-paced elderly patients maintained their original VDD mode program, with good atrial sensing.
No takes yet. Share an insight, caveat, or question.
Martinho et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: