Key result
Custom optical flow analysis successfully quantifies hiPSC-cardiomyocyte contraction pressures and detects drug and mutation responses.
Why the study?
Does a custom optical flow-based analysis method accurately quantify contraction pressure and beating frequency in normal and MYBPC3-mutated hiPSC-derived cardiomyocytes under various conditions?
Does a custom optical flow-based analysis method accurately quantify contraction pressure and beating frequency in normal and MYBPC3-mutated hiPSC-derived cardiomyocytes under various conditions?
Answers are grounded in this paper and cite their sources.
A novel optical flow-based analysis method successfully quantifies absolute contraction pressure in hiPSC-derived cardiomyocytes, demonstrating utility for medium-throughput cardiac drug development and disease modeling.
disease models and analysis methods for cardiac drug development have been insufficient in providing accurate and reliable predictions of drug efficacy and safety. Here, we propose a custom optical flow-based analysis method to quantitatively measure recordings of contracting cardiomyocytes on polydimethylsiloxane (PDMS), compatible with medium-throughput systems. Movement of the PDMS was examined by covalently bound fluorescent beads on the PDMS surface, differences caused by increased substrate stiffness were compared, and cells were stimulated with β-agonist. We further validated the system using cardiomyocytes treated with endothelin-1 and compared their contractions against control and cells incubated with receptor antagonist bosentan. After validation we examined two MYBPC3-mutant patient-derived cell lines. Recordings showed that higher substrate stiffness resulted in higher contractile pressure, while beating frequency remained similar to control. β-agonist stimulation resulted in both higher beating frequency as well as higher pressure values during contraction and relaxation. Cells treated with endothelin-1 showed an increased beating frequency, but a lower contraction pressure. Cells treated with both endothelin-1 and bosentan remained at control level of beating frequency and pressure. Lastly, both MYBPC3-mutant lines showed a higher beating frequency and lower contraction pressure. Our validated method is capable of automatically quantifying contraction of hiPSC-derived cardiomyocytes on a PDMS substrate of known shear modulus, returning an absolute value. Our method could have major benefits in a medium-throughput setting.
No takes yet. Share an insight, caveat, or question.
Snelders et al. (2022) studied Hypertrophic cardiomyopathy (in vitro model). Optical flow-based contraction analysis was evaluated on Contraction pressure (Pa) and beating rate (BPM). A custom optical flow-based analysis method successfully quantified absolute contraction pressures of hiPSC-derived cardiomyocytes, detecting expected changes in response to drugs and MYBPC3 mutations.
Synapse has enriched 10 related papers. Consider them for comparative context: