Why the study?
Prior studies characterizing very late recurrence of AF after ablation did not use implantable loop recorders, leaving it unknown whether true very late recurrence occurs or represents unrecognized AF.
What is the incidence and predictors of very late recurrence of atrial fibrillation in patients who underwent cryoballoon pulmonary vein isolation and remained AF-free for 1 year?
What is the incidence and predictors of very late recurrence of atrial fibrillation in patients who underwent cryoballoon pulmonary vein isolation and remained AF-free for 1 year?
Continuous ECG monitoring via implantable loop recorders reveals that very late recurrence of atrial fibrillation occurs in approximately one-third of patients after an apparently successful cryoballoon pulmonary vein isolation, with higher CHA2DS2-VASc scores predicting recurrence.
Answers are grounded in this paper and cite their sources.
May warrant prolonged surveillance in higher CHA2DS2-VASc patients after cryoballoon PVI; leaves open whether targeted interventions reduce very late recurrence.
Background: A very late recurrence (VLR) of atrial fibrillation (AF) is considered present when the first recurrence of AF occurs ≥12 months following ablation. Prior studies characterizing VLR have not used an implantable loop recorder for ECG monitoring. Thus, it is unknown whether VLR truly occurs or whether these patients have simply had unrecognized AF. Our objective was to assess the incidence and predictors of VLR in patients who underwent cryoballoon pulmonary vein isolation alone, had an implantable loop recorder, and were confirmed AF free for at least 1 year. Methods: We enrolled consecutive patients with paroxysmal or persistent AF who underwent cryoballoon pulmonary vein isolation and had an implantable loop recorder implanted <3 months post-ablation. Patients free of AF 1 year post-ablation were followed prospectively for recurrent AF. All AF episodes were adjudicated. Results: We included 188 patients (66±10 years; 116 [62%] men; 102 [54%] paroxysmal AF; CHA 2 DS 2 -VASc, 2.6±1.7). After 1 year post-pulmonary vein isolation, 93 (49%) patients remained AF free. During subsequent follow-up, 30 (32%) patients had VLR of AF. The only independent risk factor for VLR was an elevated CHA 2 DS 2 -VASc score (hazard ratio, 1.317 [95% CI, 1.033–1.6979]; P =0.026). Patients with CHA 2 DS 2 -VASc score ≥4 represented a quarter of the population and were at the highest risk. Conclusions: Our data using implantable loop recorders for continuous ECG monitoring post-AF ablation show that VLR occurs in a third of patients after an apparently successful cryoballoon pulmonary vein isolation procedure. Additional strategies are needed to ensure long-term freedom from AF recurrences in these high-risk patients.
No takes yet. Share an insight, caveat, or question.
Musat et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: