Key result
Trans-jugular ICE-guided noncontrast transcatheter pacing system implantation succeeds without complications in a CKD patient.
Why the study?
Cardiac perforation or effusion is reportedly more likely with transcatheter pacing systems than conventional transvenous systems, though septal implantation may reduce perforation risk compared to true apex implantation.
Case Report (n=1)
No
Implantation of a transcatheter pacing system on the septal aspect of the right ventricle, potentially guided by intracardiac echocardiography, may lower the risk of cardiac perforation compared to apical implantation.
Answers are grounded in this paper and cite their sources.
Demonstrates feasibility of noncontrast ICE-guided leadless pacing in CKD; hypothesis-generating, needs prospective validation before wider use.
Although total major complications with the transcatheter pacing system (TPS) is lower than that with conventional transvenous pacing systems, cardiac perforation or effusion is reportedly more likely to occur with TPS than with the latter in early studies.1,2 In these studies, the percentage of apex implantation was high.1 TPS implantation on the septal aspect of the right ventricle may lower the risk of perforation, when compared to implantation on the true apex, which includes the thin free wall of the right ventricle.
No takes yet. Share an insight, caveat, or question.
Otsuki et al. (2021) conducted a case report in Congestive heart failure caused by 2:1 advanced atrioventricular block (n=1). Noncontrast transcatheter pacing system (TPS) implantation guided by trans-internal jugular vein intracardiac echocardiography (ICE) was evaluated on Procedural success and complications. Noncontrast transcatheter pacing system implantation guided by trans-internal jugular vein intracardiac echocardiography was successfully performed without complications in a patient with chronic kidney disease.
Synapse has enriched 10 related papers. Consider them for comparative context: