Key result
ILR implantation predicts ~11-fold higher AF detection in ESUS patients.
Why the study?
Detection of AF in patients with ESUS is important for secondary stroke prevention, motivating an investigation into factors associated with newly diagnosed AF during follow-up.
What factors are associated with the detection of newly diagnosed atrial fibrillation in patients with embolic stroke of undetermined source?
Observational (n=312)
No
What factors are associated with the detection of newly diagnosed atrial fibrillation in patients with embolic stroke of undetermined source?
Effect estimate: HR 11.497 (95% CI 3.795-34.818)
Absolute Event Rate: 28.6% vs 4.4%
p-value: p=<0.001
Left atrial enlargement, non-sustained tachycardia, and specific ischemic lesion patterns are independent predictors of AF detection in ESUS patients, identifying a high-yield subgroup for implantable loop recorder monitoring.
ILR implantation strongly predicts AF detection in ESUS; supports targeted monitoring but leaves open whether it improves outcomes.
BACKGROUND: Detection of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS) is important for the secondary prevention of stroke. We investigated the factors associated with the detection of newly diagnosed AF in ESUS patients during follow-up. METHODS: Patients with acute ischemic stroke classified as ESUS were included. All patients underwent transthoracic echocardiography and Holter to detect the source of embolism. Structural, electrophysiological markers of left atrial cardiopathy (i.e., left atrial enlargement [LAE], non-sustained tachycardia [NSAT]) as well as lesion patterns of ischemic stroke were examined. Implantable loop recorder (ILR) was implanted in selective patients. Sensitivity and positive predictive value analysis was used to assess the predictive value for AF detection. RESULTS: Among 312 patients with ESUS, AF was detected in 24 (7.7%) patients during follow-up. Patients with AF had a higher prevalence of LAE, NSAT, and the imaging pattern of confluent plus additional lesions in a single vascular territory. Multivariable analysis showed that ILR implantation (hazards ratio 11.497 [95% confidence interval 3.795-34.818]), LAE (3.204 [1.096-9.370]), NSAT (4.070 [1.378-12.018]), and confluent plus additional lesions (4.977 [1.649-15.019]) were independent predictors of AF detection. The sensitivity of detecting AF in those with LAE, NSAT, or confluent plus additional lesions pattern was 91.7%. The positive predictive value of detecting AF in those with LAE, NSAT and confluent plus additional lesions pattern was 40.0%. CONCLUSION: In conclusion, patients with LAE, NSAT, or confluent plus additional lesions may benefit from ILR monitoring detecting new AF.
No takes yet. Share an insight, caveat, or question.
Bae et al. (2025) conducted an observational in Embolic stroke of undetermined source (ESUS) (n=312). Implantable loop recorder (ILR) vs. Routine follow-up (EKG or Holter monitoring) was evaluated on Detection of newly diagnosed atrial fibrillation (HR 11.497, 95% CI 3.795-34.818, p=<0.001). Implantable loop recorder implantation was the strongest predictor of atrial fibrillation detection (HR 11.497) in patients with embolic stroke of undetermined source.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: