Key result
Adaptive template matching of electrograms localized functional block lines bounding the central isthmus during reentry (mean 61.1% during sinus rhythm; 63.9% during ventricular pacing).
Why the study?
Does adaptive template matching of electrograms during sinus rhythm and ventricular pacing localize reentrant circuits causing ventricular tachycardia in an infarcted canine heart model?
Does adaptive template matching of electrograms during sinus rhythm and ventricular pacing localize reentrant circuits causing ventricular tachycardia in an infarcted canine heart model?
Adaptive template matching of electrograms during sinus rhythm or ventricular pacing can localize the central isthmus of reentrant ventricular tachycardia circuits without requiring reentry induction.
May aid non-inductive VT isthmus localization in infarct models; leaves open translation to clinical ablation.
INTRODUCTION: It would be advantageous, for ablation therapy, to localize reentrant circuits causing ventricular tachycardia by quantifying electrograms obtained during sinus rhythm (SR) or ventricular pacing (VP). In this study, adaptive template matching (ATM) was used to localize reentrant circuits by measuring dynamic electrogram shape using SR and VP data. METHODS AND RESULTS: Four days after coronary occlusion, reentrant ventricular tachycardia was induced in the epicardial border zone of canine hearts by programmed electrical stimulation. Activation maps of circuits were constructed using electrograms recorded from a multichannel array to ascertain block line location. Electrogram recordings obtained during SR/VP then were used for ATM analysis. A template electrogram was matched with electrograms on subsequent cycles by weighting amplitude, vertical shift, duration, and phase lag for optimal overlap. Sites of largest cycle-to-cycle variance in the optimal ATM weights were found to be adjacent to block lines bounding the central isthmus during reentry (mean 61.1% during SR; 63.9% during VP). The distance between the mean center of mass of the ten highest ATM variance peaks and the narrowest isthmus width was determined. For all VP data, the center of mass resided in the isthmus region occurring during reentry. CONCLUSION: ATM high variance measured from SR/VP data localizes functional block lines forming during reentry. The center of mass of the high variance peaks localizes the narrowest width of the isthmus. Therefore, ATM methodology may guide ablation catheter position without resorting to reentry induction.
No takes yet. Share an insight, caveat, or question.
Ciaccio et al. (2000) studied Ventricular tachycardia. Adaptive template matching (ATM) was evaluated on Localization of functional block lines bounding the central isthmus. Adaptive template matching of electrograms localized functional block lines bounding the central isthmus during reentry (mean 61.1% during sinus rhythm; 63.9% during ventricular pacing).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: