Key result
CT pulmonary vein dimensions and morphology are not linked to AF recurrence after cryoballoon ablation.
Why the study?
Recurrence of AF occurs in approximately 30% of patients after initial cryoballoon ablation, and pre-procedurally identifying patients at risk of recurrence could be beneficial.
Does pulmonary vein anatomy influence the recurrence of atrial fibrillation after second-generation cryoballoon ablation in patients with paroxysmal atrial fibrillation?
Observational (n=88)
Does pulmonary vein anatomy influence the recurrence of atrial fibrillation after second-generation cryoballoon ablation in patients with paroxysmal atrial fibrillation?
Pre-procedural CT assessment of pulmonary vein anatomy does not predict atrial fibrillation recurrence after second-generation cryoballoon ablation in patients with paroxysmal AF.
CT assessment of pulmonary vein anatomy does not predict recurrence after cryoballoon ablation; hypothesis-generating and should not yet change practice.
BACKGROUND: Cryoballoon isolation is considered a safe and effective treatment for atrial fibrillation (AF). However, recurrence of AF after first cryoballoon ablation occurs in ~30% of patients. Pre-procedurally identifying patients at risk of AF recurrence could be beneficial. HYPOTHESIS: Our aim was to determine how pulmonary vein (PV) anatomy influences the recurrence of AF using the second-generation cryoballoon in patients with paroxysmal AF. METHODS: We included 88 consecutive patients with paroxysmal AF undergoing PVI procedure with a second-generation 28-mm cryoballoon. All patients were evaluated at 3, 6 and 12 months using a 12-lead ECG and 24-hour Holter monitoring. PV anatomy was assessed by creating three-dimensional models using computed tomography (CT) segmentations of the left atrium. RESULTS: Fifty-one patients (61%) had left PVs with a shared carina, 35 patients (42%) had a shared right carina. Nine patients (11%) were classified having a right middle PV. In total 17 (20.2%) of patients had a left common PV. At 12 months, 14 patients (17%) had experienced AF recurrence. Neither PV ovality, variant anatomy, the presence of shared carina nor a common left PV was a predictor for AF recurrence. CONCLUSIONS: No specific characteristics of PV dimensions nor morphology were associated with AF recurrence after cryoballoon ablation in patients with paroxysmal AF.
No takes yet. Share an insight, caveat, or question.
Mulder et al. (2019) conducted an observational in paroxysmal atrial fibrillation (n=88). Second-generation 28-mm cryoballoon ablation was evaluated on AF recurrence. Pulmonary vein dimensions and morphology assessed by CT were not associated with atrial fibrillation recurrence (17% at 12 months) after second-generation cryoballoon ablation in paroxysmal AF.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: