Key result
Edge-based IoMT deep learning on reference-free PPG predicts real-time heart rate with ~2 BPM error.
Why the study?
Wearable sensor data require effective analysis to provide accurate and reliable estimation of vital signs such as heart rate using artificial intelligence in wearable IoMT devices.
An edge-based IoMT framework using deep learning and superlet transform on PPG signals can accurately estimate heart rate in real time without a reference signal.
May enable real-time edge-based HR monitoring in IoMT; leaves open prospective clinical validation before adoption.
Cardiovascular disease (CVD) is one of the leading causes of the mortality rate increase. To effectively analyze wearable sensor data for providing accurate and reliable estimation of vital signs, such as heart rate (HR), the use of artificial intelligence (AI) in wearable devices is increasing. The use of AI in designing healthcare wearable sensors is crucial to the uprising of the Internet of Medical Things (IoMT). The appearance of IoMT sensor technologies lets the healthcare industry shift from vis-a-vis consulting to telemedicine. IoMT sensors have transformed the healthcare industry by improving patient safety and reducing healthcare costs. This article proposes a photoplethysmogram (PPG) enabled wearable device in an edge-IoMT computing environment that enables users to monitor their real-time health status. A deep learning approach for automatic feature extraction is proposed in this work. The deep learning algorithm learns features from a super-resolution spectrogram computed using superlet transform. In the proposed system, a PPG signal is input, and the output layer provides information on HR. The proposed framework uses two publicly available PPG data sets to train and test the proposed edge-assisted model. The model is further evaluated using an in-house acquired PPG signal data set. The proposed framework obtained a mean absolute error of 0.76, 1.01, 1.46, and 1.79 BPM for IEEE Signal Processing Cup 2015 (IEEE SPC) training, IEEE SPC test, BAMI-I, and BAMI-II data sets, respectively. The proposed edge-based IoMT framework satisfactorily predicts HR in real time using reference-signal-less PPG sensor signal.
No takes yet. Share an insight, caveat, or question.
Pankaj et al. (2023) studied Heart rate estimation. Edge-based IoMT framework with deep learning and superlet transform was evaluated on Mean absolute error (MAE) of heart rate prediction. An edge-based IoMT framework using deep learning on reference-signal-less PPG signals predicted real-time heart rate with mean absolute errors ranging from 0.76 to 1.79 BPM across multiple datasets.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: