Key result
Nonrandomized studies without adjustment underestimated the benefit of transcatheter aortic valve implantation for postoperative mortality compared to high-quality RCTs.
Why the study?
Relationships between nonrandomized study design attributes and biased treatment effect estimates are poorly understood, despite widespread dependence on non-randomized studies for non-drug technologies.
Does transcatheter aortic valve implantation improve postoperative mortality compared to surgical aortic valve replacement in patients with severe aortic stenosis, and how do study design attributes affect this estimate?
Meta-Analysis (n=244,785)
Does transcatheter aortic valve implantation improve postoperative mortality compared to surgical aortic valve replacement in patients with severe aortic stenosis, and how do study design attributes affect this estimate?
Nonrandomized studies without adequate adjustment underestimate the benefit of TAVI compared to SAVR, emphasizing the need for rigorous adjustment and complete follow-up in observational research.
Answers are grounded in this paper and cite their sources.
Unadjusted observational data may reverse TAVI mortality conclusions versus RCTs; confirms need for rigorous adjustment in nonrandomized aortic valve research.
BACKGROUND: Paucity of RCTs of non-drug technologies lead to widespread dependence on non-randomized studies. Relationship between nonrandomized study design attributes and biased estimates of treatment effects are poorly understood. Our purpose was to estimate the bias associated with specific nonrandomized study attributes among studies comparing transcatheter aortic valve implantation with surgical aortic valve replacement for the treatment of severe aortic stenosis. RESULTS: We included 6 RCTs and 87 nonrandomized studies. Surgical risk scores were similar for comparison groups in RCTs, but were higher for patients having transcatheter aortic valve implantation in nonrandomized studies. Nonrandomized studies underestimated the benefit of transcatheter aortic valve implantation compared with RCTs. For example, nonrandomized studies without adjustment estimated a higher risk of postoperative mortality for transcatheter aortic valve implantation compared with surgical aortic valve replacement (OR 1.43 [95% CI 1.26 to 1.62]) than high quality RCTs (OR 0.78 [95% CI 0.54 to 1.11). Nonrandomized studies using propensity score matching (OR 1.13 [95% CI 0.85 to 1.52]) and regression modelling (OR 0.68 [95% CI 0.57 to 0.81]) to adjust results estimated treatment effects closer to high quality RCTs. Nonrandomized studies describing losses to follow-up estimated treatment effects that were significantly closer to high quality RCT than nonrandomized studies that did not. CONCLUSION: Studies with different attributes produce different estimates of treatment effects. Study design attributes related to the completeness of follow-up may explain biased treatment estimates in nonrandomized studies, as in the case of aortic valve replacement where high-risk patients were preferentially selected for the newer (transcatheter) procedure.
No takes yet. Share an insight, caveat, or question.
Youn et al. (2021) conducted a meta-analysis in Severe aortic stenosis (n=244,785). Transcatheter aortic valve implantation (TAVI) vs. Surgical aortic valve replacement (SAVR) was evaluated on Postoperative mortality (high quality RCTs) (OR 0.78, 95% CI 0.54 to 1.11). Nonrandomized studies without adjustment underestimated the benefit of transcatheter aortic valve implantation for postoperative mortality compared to high-quality RCTs.