Key result
Discharge SBP >150 mm Hg linked to ~221% higher mortality after type A aortic dissection repair.
Why the study?
Long-term optimal blood pressure and heart rate targets in patients after surgical repair of acute type A aortic dissection remain unclear.
Are higher systolic blood pressure and heart rate associated with worse long-term outcomes in patients after surgical repair of type A aortic dissection?
Cohort (n=839)
Are higher systolic blood pressure and heart rate associated with worse long-term outcomes in patients after surgical repair of type A aortic dissection?
In patients surviving surgical repair of type A aortic dissection, discharge systolic blood pressure >150 mm Hg and heart rate >80 beats/min are associated with significantly increased risks of long-term mortality and subsequent aortic events.
BACKGROUND: The long-term optimal targets for blood pressure and heart rate in patients after surgical repair of acute type A aortic dissection (TAAD) remain unclear. This study evaluated the long-term association of blood pressure and heart rate control on patients after TAAD surgical repair. METHODS: We identified 839 patients who underwent TAAD surgical repair and survived to discharge between 2003 and 2018 from the Chang Gung Research Database. Primary outcomes included all-cause mortality, aortic progression, and aortic surgery events. Vital signs examined were systolic blood pressure (SBP), diastolic blood pressure, and heart rate (HR) at discharge and at 3 months of follow-up. RESULTS: The patients were a mean age of 57.2 ± 13.6 years, and approximately two-thirds were men. The results showed that SBP >150 mm Hg at discharge was correlated with increased all-cause mortality (adjusted hazard ratio [aHR], 3.21; 95% CI, 1.61-6.37). Moreover, an HR between 81 and 100 beats/min was associated with a higher hazard of all-cause mortality (aHR, 2.59; 95% CI, 1.28-5.24) and an HR >100 beats/min was also associated with a higher hazard of aortic surgery events (aHR, 2.19; 95% CI 1.24-3.86) compared with an HR of ≤80 beats/min at discharge. During the 3-month follow-up, an HR >100 beats/min was associated with a higher hazard of all-cause mortality (aHR, 3.59; 95% CI, 1.19-10.78) relative to an HR ≤80. CONCLUSIONS: The careful management of blood pressure and HR contributes to favorable long-term outcomes in patients after surgical repair of TAAD.
No takes yet. Share an insight, caveat, or question.
Ho et al. (2025) conducted a cohort in Acute type A aortic dissection (TAAD) after surgical repair (n=839). Systolic blood pressure >150 mm Hg and heart rate >80 beats/min vs. Heart rate ≤80 beats/min and lower systolic blood pressure was evaluated on All-cause mortality (aHR 3.21, 95% CI 1.61-6.37). Systolic blood pressure >150 mm Hg at discharge was associated with increased all-cause mortality (aHR 3.21; 95% CI 1.61-6.37) in patients after surgical repair of type A aortic dissection.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: