Validation study demonstrates improved parameter accuracy and lesion contrast across simulated and human brain MRI scans, indicating greater clinical utility for intravoxel incoherent motion imaging.
Background The intravoxel incoherent motion (IVIM) parameter estimation is affected by noise, while existing CNN‐based fitting methods utilize neighborhood spatial features around voxels to obtain more robust parameters. However, due to the heterogeneity of tissue, neighborhood features with low similarity can lead to excessively smooth parameter maps and even loss of tissue details. Purpose To propose a novel neural network fitting approach, IVIM‐CNN similar , which utilizes similar neighborhood information of voxels to assist in the estimation of IVIM parameters in diffusion‐weighted imaging (DWI). Methods The proposed fitting model is based on convolutional neural network (CNN), which first identifies the similar neighborhoods of voxels through cluster analysis and then uses CNN to learn the spatial features of similar neighborhoods to reduce the impact of noise on the parameter estimation of the voxel. To evaluate the performance of the proposed method, comparisons were conducted with the least squares (LSQ), Bayesian, PI‐DNN, and IVIM‐CNN unet algorithms on both simulated and in vivo brains, including 23 healthy brains and three brain tumors, in terms of root mean square error (RMSE) of IVIM parameters and the parameter contrast ratio between the tumor and normal regions. Results The CNN‐based methods, such as IVIM‐CNN similar and IVIM‐CNN unet , yield smoother parameter maps compared to voxel‐based methods like nonlinear least squares, segmented nonlinear least squares, Bayesian, and PI‐DNN. Additionally, the IVIM‐CNN similar retains more local tissue details while maintaining smoothness of parameter maps compared to the IVIM‐CNN unet . In simulated experiments, IVIM‐CNN similar outperforms IVIM‐CNN unet in terms of parameter estimation accuracy (SNR = 30; RMSE [] = 0.0168 vs. 0.0253; RMSE () = 0.0001 vs. 0.0002; RMSE [] = 0.0266 vs. 0.0416). In addition, compared with other methods, the proposed IVIM‐CNN similar is more robust to noise, which is reflected in the lower RMSE of each parameter at different SNRs. For in vivo brains, compared to other methods, IVIM‐CNN similar achieved the highest PCR for most parameters when comparing the normal and tumor regions. Conclusions The IVIM‐CNN similar method uses similar neighborhood information to assist IVIM parameter fitting by reducing the impact of noise on voxel parameter estimation, thereby improving the accuracy of parameter estimation and increasing the potential for IVIM clinical application.
No takes yet. Share an insight, caveat, or question.
Luo et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: