Why the study?
Prompt detection of myocardial infarction is critical to reduce mortality, but existing identification methods suffer from overfitting and high computational burden in real-time scenarios.
Does the SSS-DRN model improve the accuracy of myocardial infarction detection from ECG signals compared to traditional schemes?
Does the SSS-DRN model improve the accuracy of myocardial infarction detection from ECG signals compared to traditional schemes?
The proposed SSS-DRN model provides highly accurate early detection of myocardial infarction from ECG signals, potentially improving real-time clinical decision-making in hospital and mobile health settings.
May improve real-time MI detection from ECG in clinical settings; extends traditional schemes for prospective validation.
Globally, the high number of deaths are happening due to Myocardial infarction (MI). MI is considered as a life-threatening disease, which leads to an increase number of deaths or damage to the heart, and hence, prompt detection of MI is critical to decrease the mortality rate. Though, numerous works have addressed MI identification, an increased number suffer from over fitting and high computational burden in real-time scenarios. The proposed system introduces a novel MI detection technique using a Deep Residual Network (DRN), where the solution is optimized by the proposed Social Ski-Spider (SSS) Optimization algorithm is the novel combination of both Social Ski-driver (SSD) Optimization and the Spider Monkey Optimization (SMO). This model highly prevents the overfitting and computational burden, which increases the MI detection accuracy. Here, the proposed SSS-DRN performs detection by filtering the electrocardiography (ECG) signals. Later, the signal feature, transform feature, medical feature and statistical feature are extracted by the feature extraction phase followed by data augmentation that consists of permutation, random generation and re-sampling processes and finally, detection is accomplished by the SSS-DRN. Moreover, the developed SSS-DRN is researched for its efficiency considering metrics like accuracy, sensitivity, and specificity and observed 0.916, 0.921, and 0.926. Here, when considering the accuracy metrics, the performance gain observed by the devised model is 13.96%, 12.61%, 10.37%, 7.95%, 5%, 2.21%, and 2% higher than the traditional schemes. This indicates the devised model has high detection accuracy, which could be embedded in real-time clinical settings like hospital ECG machines, wearable ECG monitors, and mobile health applications. This improves the clinical decision-making process with increased patient outcomes.
No takes yet. Share an insight, caveat, or question.
Bharathi et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: