Evaluates zirconia frameworks' adaptation in implant-supported prostheses, highlighting AI's promise in assessment.
STATEMENT OF PROBLEM: Despite the increased use of direct-to-abutment connections for implant-supported fixed complete dental prostheses (ISFCDPs), limited evidence exists regarding marginal adaptation and internal fit, 2 parameters critical for biomechanical performance. PURPOSE: This study evaluated the marginal adaptation and internal fit of zirconia frameworks with direct-to-abutment connections compared to conventional titanium base (Ti-base) connections. A novel method for internal fit assessment using a deep learning artificial intelligence (AI) model was also introduced, and level of agreement with traditional measurements was assessed. Internal fit was compared across the 3 designs using both traditional and AI-derived measurements. MATERIAL AND METHODS: Zirconia specimens (n=24) were allocated to 3 groups: frameworks with Ti-base and regular screws (n=8), frameworks fabricated direct-to-abutment with regular screws (n=8), and frameworks fabricated direct-to-abutment with modified screws (n=8). Each specimen underwent microcomputed tomography scanning before and after thermomechanical aging (TMA) to assess internal fit and marginal adaptation. A deep learning-based AI segmentation model was developed using an image processing software program and achieved a final validation loss below 0.01, corresponding to a Dice Similarity Coefficient greater than 0.95. This metric indicates high spatial overlap and robust segmentation of the gap and abutment regions. Volumetric measurements were obtained for 1 straight and 1 angled transmucosal abutment per specimen. Specimens were subjected to 1.2 million loading cycles at 90 N, followed by repeated measurements. Ninety-six sites were evaluated before and after TMA. Two measurements each for straight and angled abutments for the 3 designs were averaged and difference scores were calculated as post-TMA minus pre-TMA values. Nonparametric statistical tests were applied because of heterogeneity of group variances. Post hoc Mann-Whitney U tests, intraclass correlation and Bland-Altman analyses were conducted (α=.05). RESULTS: Significant differences in marginal adaptation among the 3 groups were identified before and after TMA. The Ti-base group demonstrated significantly superior marginal adaptation compared to both direct-to-abutment groups at both time points (z=3.36, P<.001). Significant differences in internal fit were also observed among the 3 groups before and after TMA. Ti-base group showed significantly improved internal fit relative to both direct-to-abutment groups (standardized Mann-Whitney z values ranged from 3.15 to 3.36, P<.001). Intraclass correlations revealed a significant level of agreement between standardized measurements obtained using conventional and AI-based methods (P<.001), and Bland-Altman plots provided support for concurrent validity of the AI-derived measures of internal fit. CONCLUSIONS: Ti-base connections in ISFCDPs demonstrated superior marginal adaptation and internal fit compared to direct-to-abutment connections. Both connection designs achieved clinically acceptable internal fit values. For marginal adaptation, the direct-to-abutment regular screw group exceeded the clinically acceptable threshold of 120 µm. A significant level of agreement was found between standardized traditional and AI-derived measurements of internal fit. Bland-Altman plots supported the concurrent validity of the deep learning AI model.
No takes yet. Share an insight, caveat, or question.
Alzoubi et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: