Key result
Radiofrequency balloon PVI achieves ~83% freedom from atrial tachyarrhythmias with minimal major complications.
Why the study?
The study was designed to evaluate the midterm clinical outcome and predictors of single-shot pulmonary vein isolation using the multielectrode radiofrequency balloon catheter.
Does pulmonary vein isolation with the radiofrequency balloon catheter safely and effectively prevent atrial tachyarrhythmias in patients with symptomatic paroxysmal or persistent atrial fibrillation?
Observational (n=104)
No
Does pulmonary vein isolation with the radiofrequency balloon catheter safely and effectively prevent atrial tachyarrhythmias in patients with symptomatic paroxysmal or persistent atrial fibrillation?
The novel radiofrequency balloon catheter provides safe and effective pulmonary vein isolation with an 82.9% freedom from atrial tachyarrhythmias at 10 months and a 1% major complication rate.
Supports radiofrequency balloon PVI feasibility in paroxysmal/persistent AF; leaves open need for randomized comparisons versus established catheters.
AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.
No takes yet. Share an insight, caveat, or question.
Monte et al. (2023) conducted an observational in Symptomatic paroxysmal or persistent atrial fibrillation (n=104). Pulmonary vein isolation with the radiofrequency balloon catheter (RFB) was evaluated on Freedom from any atrial tachyarrhythmias lasting >30 s during the follow-up after a 3-month blanking period. Pulmonary vein isolation with the radiofrequency balloon catheter achieved an 82.9% freedom from atrial tachyarrhythmias at a mean follow-up of 10.1 months, with a 1% major complication rate.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: