Key result
CTCA imaging errors minimally impact shear stress and SmartFFR but significantly alter plaque growth variables.
Why the study?
CTCA image acquisition and arterial reconstruction introduce errors that may propagate, potentially affecting computational results and the accuracy of diagnostic and prognostic coronary disease models.
Observational (n=20)
Imaging errors in CTCA reconstruction can significantly propagate into computational plaque growth models, though diagnostic indices like SmartFFR appear more robust.
Answers are grounded in this paper and cite their sources.
SmartFFR appears robust to CTCA errors; leaves open reliability of plaque growth models for research use.
Assessments of coronary artery disease can be achieved using non-invasive computed tomography coronary angiography (CTCA). CTCA can be further used for the 3D reconstruction of the coronary arteries and the development of computational models. However, image acquisition and arterial reconstruction introduce an error which can be propagated, affecting the computational results and the accuracy of diagnostic and prognostic models. In this work, we investigate the effect of an imaging error, propagated to a diagnostic index calculated using computational modelling of blood flow and then to prognostic models based on plaque growth modelling or binary logistic predictive modelling. The analysis was performed utilizing data from 20 patients collected at two time points with interscan period of six years. The collected data includes clinical and risk factors, biological and biohumoral data, and CTCA imaging. The results demonstrated that the error propagated and may have significantly affected some of the final outcomes. The calculated propagated error seemed to be minor for shear stress, but was major for some variables of the plaque growth model. In parallel, in the current analysis SmartFFR was not considerably affected, with the limitation of only one case located into the gray zone.
No takes yet. Share an insight, caveat, or question.
Sakellarios et al. (2021) conducted an observational in Coronary artery disease (n=20). CTCA-based computational modelling was evaluated on Propagated imaging error in diagnostic and prognostic models. Imaging error propagation in CTCA-based computational models had a minor effect on shear stress and SmartFFR, but significantly affected some variables of the plaque growth model.
Synapse has enriched 10 related papers. Consider them for comparative context: