Key result
Recalibration using freshly collected human sera in a regional standardization program resulted in all 12 participating laboratories achieving a mean HDL cholesterol bias ≤5%.
Why the study?
Does the use of freshly collected, never-frozen human sera improve the interlaboratory standardization and accuracy of lipid profile assays compared to frozen sera?
Observational
Yes
Does the use of freshly collected, never-frozen human sera improve the interlaboratory standardization and accuracy of lipid profile assays compared to frozen sera?
Freshly collected, never-frozen human sera are necessary for accurate interlaboratory standardization of lipid profiles, as frozen sera introduce significant matrix biases.
Answers are grounded in this paper and cite their sources.
Supports regional HDL standardization with fresh sera; leaves open effects on clinical lipid assay accuracy.
The Clinical Chemistry Forum of Central Virginia initiated a lipid standardization program to help ensure that its members meet the current National Cholesterol Education Program guidelines for cholesterol testing, and to standardize assays of high-density lipoprotein (HDL) cholesterol and triglycerides so as to provide accurate lipid profiles. We found that freshly collected, never-frozen human sera must be used to assess interlaboratory accuracy for cholesterol, HDL cholesterol, and triglycerides assays, and that at least 23 samples are required to detect a 3% bias with 90% power when the between-laboratory imprecision (CV) is 3%. After recalibration, all 12 laboratories had a mean HDL cholesterol bias less than or equal to 5%, nine of 10 laboratories had a mean HDL cholesterol bias less than or equal to 40 mg/L for samples with values less than or equal to 570 mg/L, and 10 of 12 laboratories had a mean triglycerides bias less than or equal to 10% for fresh human sera split between participants and the Centers for Disease Control. Pools of frozen human sera were shown to have matrix biases greater than 3% for cholesterol in seven of 11 laboratories, and greater than 40 mg/L for HDL cholesterol in six of nine laboratories.
No takes yet. Share an insight, caveat, or question.
Tetrault et al. (1990) conducted an observational in Lipid testing accuracy. Recalibration using freshly collected human sera vs. Frozen human sera was evaluated on Mean HDL cholesterol and triglycerides bias. Recalibration using freshly collected human sera in a regional standardization program resulted in all 12 participating laboratories achieving a mean HDL cholesterol bias ≤5%.