A novel cloud point extraction method has been developed for the simultaneous isolation of uranium and thorium from carbonate microsamples. This method offers an alternative to conventional ion-exchange chromatography for uranium and thorium purification prior to high-sensitivity determination by ICP-MS. For this, Triton X-114, cetyl trimethyl ammonium bromide (CTAB) and H 2 DEH[MDP] (P,P-di(2-ethylhexyl) methanediphosphonic acid) were used. Quantities of extraction reagents were first optimized to determine the threshold values allowing quantitative extraction of U and Th in the case of a 1 mg carbonate sample containing up to 2 μg g −1 of U and Th combined. Competitiveness was also investigated and the developed CPE system allowed a selective extraction of U and Th even in the simultaneous presence of several μg mL −1 of calcium and magnesium. Additionally, resolubilization of the surfactant rich phase (SRP) was investigated and reduced to 100 μL to ensure maximal analyte signals during analysis. Finally, phase separation temperature was identified as a key parameter controlling analyte extraction rates and 23 °C was determined as the optimal temperature to ensure systematic quantitative extraction of both elements. Samples were analyzed using manual micro-injection into the ICPMS. Under these conditions, the recovery of uranium and thorium was found to be within 98% and 105%, respectively. The signal reproducibility (peak integration) was measured at 3.4% and 6.9% (2xRSD, n = 5) for thorium and uranium, respectively. The developed method could thus be proposed for U/Th dating of speleothems from micro-samples, which could prove valuable in the context of cave studies subjected to stringent preservation requirements. • Development of a H 2 DEH[MDP]-based CPE system for U and Th quantitative co-extraction from aqueous sample in acidic conditions. • Extraction reagents quantities were optimized and decreased by 33% compared to initial conditions. • Extraction of U and Th remained quantitative, even in the presence of several μg.mL −1 of Ca and Mg. • No significant elemental and isotopic fractionation were observed. • Coacervate resolubilization volume successfully decreased from 5 mL to 100 μL which significantly increased analytes signals.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Boccas et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: