Key result
Post-TAVI prosthesis-patient mismatch is linked to ~257% more exercise-induced pulmonary hypertension without affecting major events.
Why the study?
Evidence was lacking on hemodynamic performance during exercise and the impact of prosthesis-patient mismatch on transcatheter heart valve hemodynamics after TAVI.
Does prosthesis-patient mismatch (PPM) worsen hemodynamics during exercise and increase adverse clinical outcomes in patients with aortic stenosis after TAVI?
Cohort (n=77)
No
Does prosthesis-patient mismatch (PPM) worsen hemodynamics during exercise and increase adverse clinical outcomes in patients with aortic stenosis after TAVI?
In patients undergoing TAVI, prosthesis-patient mismatch is associated with worsened hemodynamics and exercise-induced pulmonary hypertension, though it did not significantly impact mid-term clinical outcomes in this small cohort.
Answers are grounded in this paper and cite their sources.
PPM after TAVI was associated with exercise pulmonary hypertension but not outcomes; leaves open prognostic relevance in larger studies.
Background There is no evidence of hemodynamic performance during exercise in patients with aortic stenosis (AS) after transcatheter aortic valve implantation (TAVI). This study aimed to investigate the changes in kinematic hemodynamics during exercise and determine the impact of prosthesis-patient mismatch (PPM) on the hemodynamics of transcatheter heart valves using exercise stress echocardiography (ESE) in AS patients after TAVI. Methods and Results This study enrolled 77 consecutive patients (mean age 82 ± 5 years, 50.6% male) who underwent ESE 3–6 months after TAVI with a balloon-expandable valve. The effective orifice area index at rest was significantly correlated with the mean pressure gradient (PG) during exercise ( p <0.001). The patients were divided into two groups according to the presence of PPM (PPM and non-PPM groups). During exercise, the patients with PPM had a higher left ventricular ejection fraction (74.6 ± 6.1% vs. 69.7 ± 9.6%, p = 0.048), a lower stroke volume index (47.2 ± 14.0 ml/m 2 vs. 55.6 ± 14.5 ml/m 2 , p = 0.037), a significantly higher mean transvalvular PG (21.9 ± 9.1 mmHg vs. 12.2 ± 4.9 mmHg, p = 0.01) and an increased mean PG from rest to exercise (5.7 ± 3.5 mmHg vs. 2.3 ± 2.8 mmHg, p <0.001) compared with patients without PPM. Patients with PPM had a higher pulmonary artery systolic pressure (SPAP) during exercise (57.3 ± 13.8 mmHg vs. 49.7 ± 10.9 mmHg, p = 0.021) and a higher incidence of exercise-induced pulmonary hypertension (43.8 vs. 15.0%, p = 0.037) than patients without PPM. PPM was strongly associated with exercise-induced pulmonary hypertension (hazard ratio: 3.570, p = 0.013). Conclusions AS patients with PPM after TAVI showed a disproportionate increase in the transvalvular PG and SPAP during exercise, and PPM was associated with exercise-induced pulmonary hypertension.
No takes yet. Share an insight, caveat, or question.
Kameshima et al. (2022) conducted a cohort in Aortic stenosis after transcatheter aortic valve implantation (n=77). Prosthesis-patient mismatch (PPM) vs. No prosthesis-patient mismatch (non-PPM) was evaluated on Composite of all-cause mortality, cardiovascular mortality, cardiovascular event, and heart failure-related hospitalization (p=0.647). Prosthesis-patient mismatch after TAVI was associated with exercise-induced pulmonary hypertension (HR 3.570) but did not significantly affect the primary composite clinical endpoint (p=0.647).