Key result
Prosthesis-patient mismatch after TAVI was associated with a higher rate of failure to improve in functional class compared to no mismatch.
Why the study?
Prosthesis-patient mismatch occurs after aortic valve surgery, but little was known about its incidence and mid-term hemodynamic and clinical impact after TAVI with balloon-expandable valves.
Does prosthesis-patient mismatch after TAVI with balloon-expandable valves worsen hemodynamic and clinical outcomes in patients with aortic stenosis?
Cohort (n=165)
Does prosthesis-patient mismatch after TAVI with balloon-expandable valves worsen hemodynamic and clinical outcomes in patients with aortic stenosis?
Answers are grounded in this paper and cite their sources.
Prosthesis-patient mismatch occurs in nearly 20% of TAVI patients and is associated with worse hemodynamic profiles and less improvement in functional status at 6 months.
OBJECTIVES: This study examined the mid-term hemodynamic and clinical impact of prosthesis-patient mismatch (PPM) in patients undergoing transcatheter aortic valve implantation (TAVI) with balloon-expandable valves. BACKGROUND: PPM can be observed after aortic valve surgery. However, little is known about the incidence of PPM in patients undergoing TAVI. METHODS: Echocardiography and clinical assessment were performed in 165 patients at baseline, before hospital discharge, and at 6 months after TAVI. PPM was defined as an indexed effective orifice area ≤0.85 cm(2)/m(2). RESULTS: Thirty patients (18.2%) showed PPM before hospital discharge. At baseline, patients with PPM had a larger body surface area (1.84 ± 0.18 m(2) vs. 1.73 ± 0.18 m(2), p = 0.003) and a greater severity of aortic stenosis (indexed valve area 0.35 ± 0.09 cm(2)/m(2) vs. 0.40 ± 0.10 cm(2)/m(2), p = 0.005) than patients without PPM. Patients with PPM demonstrated a slower and smaller reduction in mean transaortic gradient, limited left ventricular (LV) mass regression, and left atrial volume reduction over 6 months compared with patients without PPM. LV filling pressure, measured by E/e', tended to remain elevated in patients with PPM. Importantly, a higher proportion of patients with PPM did not improve in New York Heart Association functional class compared with patients without PPM (36.7% vs. 1.5%, p < 0.001), although major adverse valve-related and cardiovascular events did not differ between the 2 groups. CONCLUSIONS: PPM may be observed after TAVI and when present may be accompanied by less favorable changes in transvalvular hemodynamics, limited LV mass regression, persistent elevated LV filling pressure, and less improvement in clinical functional status.
No takes yet. Share an insight, caveat, or question.
Ewe et al. (2011) conducted a cohort in Aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) (n=165). Prosthesis-patient mismatch (PPM) vs. No prosthesis-patient mismatch was evaluated on Failure to improve in New York Heart Association (NYHA) functional class (p=<0.001). Prosthesis-patient mismatch after TAVI was associated with a higher rate of failure to improve in functional class compared to no mismatch.