Key result
3D EAM without ICE is linked to ~87% less fluoroscopy time versus conventional PSVT ablation.
Why the study?
Radiation exposure during fluoroscopic procedures increases cancer risk for patients and operators, prompting evaluation of the safety and efficacy of a 3D electroanatomical mapping system without intracardiac echocardiography for PSVT ablation.
Does a 3D EAM system without ICE reduce fluoroscopy time and maintain efficacy compared to conventional ablation in adult patients with PSVT?
Cohort (n=328)
Does a 3D EAM system without ICE reduce fluoroscopy time and maintain efficacy compared to conventional ablation in adult patients with PSVT?
Absolute Event Rate: 100% vs 99.1%
The use of a 3D electroanatomical mapping system without intracardiac echocardiography for PSVT ablation significantly reduces fluoroscopy time while maintaining high acute success rates, though it slightly increases procedure time.
Supports 3D EAM without ICE to minimize radiation in PSVT ablation; leaves open need for RCTs before practice change.
Background: Radiation exposure during fluoroscopic procedures increases the risk of cancer for both patients and operators. Objectives: The aim of this study was to investigate the safety and efficacy of adopting a three-dimensional electroanatomical mapping (3D EAM) system during ablation for paroxysmal supraventricular tachycardia (PSVT), without the assistance of intracardiac echocardiography (ICE), for both right- and left-chamber cardiac procedures. Methods: We retrospectively enrolled all patients with PSVT from September 2018 to December 2020. The patients were grouped according to the use of the 3D EAM system (3D-guided group, n = 102 vs. conventional group, n = 226). Results: The acute success rates were high in both groups (100% vs. 99.1%). The fluoroscopy time was significantly lower in the 3D-guided group than in the conventional group (2.4 ± 4.4 vs. 19.0 ± 10.8 min); the procedure time was significantly increased in the 3D-guided group (104.5 ± 29.9 vs. 94.0 ± 31.9 min), and this was associated with the post-electrophysiology test diagnosis after adjustment for multiple variables [standardized B coefficient (β) 0.188]. There was no learning curve for each electrophysiologist in terms of fluoroscopy and procedure times. Conclusions: The 3D EAM system, without the assistance of ICE, was safe and effective in guiding PSVT ablation in both left- and right-chamber ablation.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2023) conducted a cohort in Paroxysmal supraventricular tachycardia (PSVT) (n=328). Three-dimensional electroanatomical mapping (3D EAM) system without intracardiac echocardiography (ICE) vs. Conventional ablation was evaluated on Acute success rate. A 3D EAM system without ICE for PSVT ablation achieved high acute success (100% vs. 99.1%) and reduced fluoroscopy time (2.4 vs. 19.0 min) compared to conventional ablation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: