Key result
Contact force-guided radiofrequency and second-generation cryoballoon ablation show comparable 12-month AF recurrence and complications.
Why the study?
To evaluate the safety and efficacy of pulmonary vein isolation in patients with paroxysmal AF using cryoballoon ablation versus contact force-sensing radiofrequency ablation.
Does radiofrequency ablation with contact force sensing reduce atrial fibrillation recurrence compared to cryoballoon ablation in patients with paroxysmal atrial fibrillation?
Cohort (n=50)
No
Does radiofrequency ablation with contact force sensing reduce atrial fibrillation recurrence compared to cryoballoon ablation in patients with paroxysmal atrial fibrillation?
Contact force-guided radiofrequency ablation and second-generation cryoballoon ablation offer comparable procedural safety and 12-month arrhythmia-free survival for patients with paroxysmal atrial fibrillation.
Does not warrant changing ablation technique selection; leaves open comparative effectiveness pending randomized trials.
AIM: Evaluation of the safety and efficacy of pulmonary veins isolation in patients with paroxysmal atrial fibrillation (AF) using two new different technologies, cryoballoon (CB) ablation and radiofrequency ablation with contact force (CF)-sensing catheters. METHODS: Prospective single-center evaluation, carried out from January 2016 to June 2018 in Critical Care Medicine Department – Cairo University, comparing CF radiofrequency (Thermocool® SmartTouch, Biosense Webster, Inc.) (CF group) with CB ablation (Arctic Front Advance 28 mm CB, Medtronic, Inc.) (CB group), in regards to procedural safety and efficacy, as well as recurrence at 12 months. Overall, 50 consecutive patients were enrolled (25 in each group). RESULTS: The characteristics of patients of both the groups were similar (46.9 ± 11.2 years, the proportion of women 36%, mean documented AF duration 3 ± 2.3 years, mean CHA2DS2-VASc score 1.4 ± 1.3, and mean HAS-BLED 1.4 ± 0.6). Duration of the procedure was significantly lower in the CB group (171.7 ± 15.24 vs. 199.3 ± 18.94 min, p = 0.002), with a longer duration of fluoroscopy and X-ray exposure in the CB group than the CF group but statistically non-significant difference (58.60 ± 11.57 vs. 48.7 ± 13.86 min and 6273 ± 4934 cGy cm² vs. 6853 ± 5069 cGy cm², p = 0.1 and p = 0.2, respectively). Overall complication rate was similar in both groups: 2 (8%) in each group. At 12 months, AF recurrence occurred in 7 patients (28%) in the CF group and in 9 patients (36%) in the CB group (log rank p = 0.682). CONCLUSION: Pulmonary vein isolation using CF-guided RF and second-generation CB leads to comparable single-procedure arrhythmia-free survival at up to 12 months with similar overall complication rate.
No takes yet. Share an insight, caveat, or question.
Hassan et al. (2020) conducted a cohort in Paroxysmal Atrial Fibrillation (n=50). Contact force-sensing radiofrequency ablation vs. Cryoballoon ablation was evaluated on Atrial fibrillation recurrence at 12 months (p=0.682). Contact force-guided radiofrequency ablation and second-generation cryoballoon ablation resulted in comparable 12-month atrial fibrillation recurrence rates (28% vs 36%, p=0.682) and overall complication rates.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: