Answers are grounded in this paper and cite their sources.
Using representative numerical models of eight code-designed steel moment-resisting frame buildings and several ground motions, time-history analyses are performed and a critical evaluation of Peak Horizontal Floor Acceleration (PHFA) demands is conducted. The frames are modeled alternatively as linear and nonlinear systems to isolate the effect of building nonlinearity on PHFA. In most cases, PHFA is reduced when nonlinear behavior of a building is considered; however, in some cases, significant amplification of PHFA is observed. Results from the numerical study provide insight into the trend of modal response modification factors presented taking ground motion spectral shape into account.
No takes yet. Share an insight, caveat, or question.
Ray‐Chaudhuri et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: