Thermal unit commitment (UC) is a nonlinear combinatorial optimization problem that minimizes total operating costs while considering system load balance, on/off restrictions and other constraints. Successfully solving the thermal UC problem contributes to a more reliable power system and reduces thermal costs. This paper presents an exact mixed-integer quadratic programming (EMIQP) method for large-scale thermal UC problems. EMIQP revolutionizes the landscape by seamlessly translating the intricate nonlinear combinatorial optimization problem of UC into an exact mixed-integer quadratic formulation. This approach also elegantly reimagines on/off constraints as mixed-integer linear equations, employing both the sum and respective approaches. Our case studies unequivocally demonstrate the exceptional prowess of the EMIQP method, consistently securing the global optimum. Moreover, the mathematical-based EMIQP method produces identical results at each run, which is extremely important for UC in the real world.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Kang et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: