A new membrane filter medium was developed for the improved recovery of injured coliforms from drinking water. The new medium, termed m-T7, consists of 5.0 g of Difco Proteose Peptone no. 3, 20 g of lactose, 3.0 g of yeast extract, 0.4 ml of Tergitol 7 (25% solution), 5.0 g of polyoxyethylene ether W-1, 0.1 g of bromthymol blue, 0.1 g of bromcresol purple, and 15 g of agar per liter of distilled water. Additional selectivity may be obtained by aseptically adding 0.1 microgram of penicillin G per ml to the medium after autoclaving. In laboratory studies, m-T7 agar recovered 86 to 99% more laboratory-injured coliforms than did m-Endo agar. m-T7 agar also recovered an average of 43% more verified coliforms from 67 surface and drinking water samples than did the standard m-Endo membrane filter technique. From drinking water, m-T7 agar recovered nearly three times more coliforms than did m-Endo agar. Less than 0.5% of the colonies on m-T7 agar gave false-negative reactions, whereas greater than 70% of the typical yellow colonies from m-T7 agar produced gas in lauryl tryptose broth. Most of the verified coliforms isolated on m-T7 agar belonged to one of the four common coliform genera: Escherichia, 17.6%; Klebsiella, 21.7%; Citrobacter, 17.3%; Enterobacter, 32.2%. The results demonstrate that m-T7 agar is superior to m-Endo agar, especially for the isolation of injured coliforms from drinking water.
No takes yet. Share an insight, caveat, or question.
LeChevallier et al. (1983) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: