Key result
Combined self-reference and iPASO pace mapping successfully eliminates non-pulmonary vein triggers in paroxysmal AF.
Why the study?
Non-PV triggers drive AF recurrence in some patients after PV isolation, but localizing these triggers for ablation can be challenging.
Does the combined use of self-reference mapping and iPASO mapping enable the identification and ablation of non-pulmonary vein triggers in paroxysmal atrial fibrillation?
Case Report (n=1)
Does the combined use of self-reference mapping and iPASO mapping enable the identification and ablation of non-pulmonary vein triggers in paroxysmal atrial fibrillation?
A multimodal approach combining self-reference mapping and iPASO mapping can successfully identify and guide the ablation of non-pulmonary vein triggers in patients with paroxysmal atrial fibrillation.
Supports feasibility of combined mapping for non-PV triggers in one case; leaves open confirmation of benefit in prospective studies.
BACKGROUND: Pulmonary vein (PV) isolation is a well-established and effective treatment for paroxysmal atrial fibrillation (AF). However, in some patients, AF recurrence is driven by non-PV triggers. Identifying these triggers is crucial for achieving long-term ablation success, but their localization can be challenging. CASE SUMMARY: This report presents the case of paroxysmal AF in which the combined use of self-reference mapping and atrial pace mapping using Intracardiac Pace Match Scoring (iPASO) enabled successful identification and ablation of multiple non-PV triggers, resulting in a satisfactory outcome. DISCUSSION: To the best of our knowledge, this is the first reported case in which multiple non-PV triggers were successfully eliminated through the combined use of self-reference mapping and iPASO mapping. TAKE-HOME MESSAGE: A multimodal approach, combining self-reference mapping and iPASO mapping, may be a useful strategy for identifying and managing non-PV triggers in clinical practice.
No takes yet. Share an insight, caveat, or question.
Kato et al. (2026) conducted a case report in paroxysmal atrial fibrillation (n=1). Self-reference mapping and atrial pace mapping using Intracardiac Pace Match Scoring (iPASO) was evaluated on Identification and ablation of multiple non-pulmonary vein triggers. The combined use of self-reference mapping and atrial pace mapping using iPASO successfully identified and eliminated multiple non-pulmonary vein triggers in a patient with paroxysmal AF.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: