Answers are grounded in this paper and cite their sources.
Variable stiffness actuation (VSA) devices are being used to jointly address the issues of safety and performance in physical human-robot interaction. With reference to the VSA-II prototype, we present a feedback linearization approach that allows the simultaneous decoupling and accurate tracking of motion and stiffness reference profiles. The operative condition that avoids control singularities is characterized. Moreover, a momentum-based collision detection scheme is introduced, which does not require joint torque sensing nor information on the time-varying stiffness of the device. Based on the residual signal, a collision reaction strategy is presented that takes advantage of the proposed nonlinear control to rapidly let the arm bounce away after detecting the impact, while limiting contact forces through a sudden reduction of the stiffness. Simulations results are reported to illustrate the performance and robustness of the overall approach. Extensions to the multidof case of robot manipulators equipped with VSA-II devices are also considered.
No takes yet. Share an insight, caveat, or question.
Luca et al. (2009) studied this question.