Key result
Circle method for estimating conduction velocity localizes radiofrequency ablated tissue in simulations and animal hearts.
Why the study?
Estimation of radiofrequency ablated area size, local conduction velocity, and general electrophysiology at ablation sites remains a challenge in clinical electrophysiology.
Does the circle method accurately estimate the size and location of radiofrequency ablated areas in isolated hearts and simulations?
Does the circle method accurately estimate the size and location of radiofrequency ablated areas in isolated hearts and simulations?
The proposed circle method accurately estimates the size and location of radiofrequency ablation lesions based on local conduction velocity in simulations and isolated animal hearts.
Should not yet guide clinical ablation assessment; leaves open in vivo human validation of conduction velocity-based lesion mapping.
Estimation of the radiofrequency ablated (RFA) area size, local conduction velocity (CVL), and general electrophysiology at the ablation sites remains a challenge in clinical electrophysiology. This study proposes a circle method (CM) for estimation of local CV vector fields, applied to identify late activation zones, and for localization and characterization of ablated tissue. The method is based on automatic detection of the wavefront propagation direction calculated along directions in circular disposition. The method robustness is tested and validated to estimate the electrophysiological effects and lesion sites after RFA ablation. RFA was modeled in simulations and performed in isolated hearts. Local CV at the center of the ablation area showed a logarithmic curve increasing with larger radius, suitable for estimating the ablated area size. From the CVL maps, distinct regions of substantially lower CVLs showed the ablated area's location. Maps of CVL directions around the ablated area show characteristic deviation symmetric regarding the propagating wavefront allowing for more accurate delineation of ablated area. The method is validated for different ablation geometries and sizes, wavefront curvatures and different animal experiments. Estimation of ablated area's size and its location could be performed without prior knowledge of the wavefront propagation direction.
No takes yet. Share an insight, caveat, or question.
Siles et al. (2021) studied Radiofrequency ablation lesions. Circle method (CM) for estimation of local conduction velocity vector fields was evaluated on Estimation of ablated area size and location. The proposed circle method for estimating local conduction velocity vector fields successfully localized and characterized radiofrequency ablated tissue in simulations and isolated animal hearts.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: