Key result
High-power short-duration AF ablation maintains sinus rhythm with ~16% recurrence.
Why the study?
Different results are described following AF ablation, prompting evaluation of the benefits of first AF ablation using the high-power short-duration technique.
Does high-power short-duration (HPSD) ablation improve outcomes and procedural efficiency in patients undergoing first atrial fibrillation ablation?
Observational (n=212)
Does high-power short-duration (HPSD) ablation improve outcomes and procedural efficiency in patients undergoing first atrial fibrillation ablation?
High-power short-duration (HPSD) ablation for atrial fibrillation demonstrates a high rate of sinus rhythm maintenance, high first-pass isolation, and short procedural times.
HPSD ablation may support durable sinus rhythm in AF; leaves open comparative efficacy and safety versus standard approaches in randomized trials.
INTRODUCTION: Different results are described after atrial fibrillation (AF) ablation and multiples predictors of recurrence are well established. Objective: Evaluate and analyze the benefits of first atrial fibrillation (AF) ablation with high-power short-duration (HPSD).METHODS: Observational, retrospective study, 212 patients submitted to High Power Short Duration AF ablation (HPSD).Ablation in left atrial posterior wall was performed with 45W with contact force of 3 to 10 grams during 4 to 6 seconds, in the anterior wall we used 50W with contact force of 5 to 20 grams during 4 to 6 seconds and a pump flow of 35ml/min.Males were 155 (73.11%), mean age 61.73 years, paroxysmal AF in 132 (62.26%), 126 (59.43%) hypertension, 96 (45.28%) obstructive apnea, 65(30.66%)arterial disease, 41(19.34%)Diabetes, and 16(7.55%)strokes.Mean time from AF diagnosis to ablation was 20.43 months CHADS 2 VASC 2 2.51.RESULTS: Mean left atrial time was 72.83 minutes, mean total procedure time 94.79 minutes, mean radiofrequency time of 1,723.8seconds, 76 (35.85%) of esophageal temperature elevation, mean Xray time of 7.58 minutes, bilateral first-pass isolation effect in 168 (79.25%) patients and mean follow-up was 22.12 (4 to 36) months and recurrence rate after blanking period occurred in 33 (15.57%) patients.Complications were local hematomas in 62 (29.25%) patients, 2 (0.94%) femoral artery pseudoaneurysm, 2 (0.94%) pericardial effusions and 1 (0.47%) cardiac tamponade occurred after transeptal puncture.CONCLUSION: HPSD showed a high rate of sinus rhythm during the follow-up.Also, we demonstrated a low rate of esophageal heating, a high rate of first-pass isolation effect and short left atrial, total ablation and radiofrequency times with HPSD technique.
No takes yet. Share an insight, caveat, or question.
Vassallo et al. (2021) conducted an observational in Atrial fibrillation (n=212). High Power Short Duration (HPSD) AF ablation was evaluated on Recurrence rate after blanking period. High-power short-duration atrial fibrillation ablation resulted in a 15.57% recurrence rate over a mean follow-up of 22.12 months, demonstrating a high rate of sinus rhythm maintenance.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: