PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 1, 20202020 Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT)0 citations

In-silico Analysis of the Role of Boundary Conditions in the Induced Drift of 2D Spiral Waves

View Full Paper
EKEvgeniy KuklinSPSergei F. Pravdin

Key Result

In-silico simulations of spiral waves on surfaces without boundaries (torus, Mobius strip, cylinder) identified approximate limits of effective pacing periods for low-voltage cardioversion.

Structured PICO

Does external stimulation from a point electrode affect the trajectories and annihilation of spiral waves in an in-silico model of cardiac tissue?

P
Population
In-silico model of cardiac tissue (isotropic medium with Aliev-Panfilov cell-level model) on surfaces: torus, Mobius strip, and cylinder
I
Intervention
External stimulation from a point electrode (low-voltage cardioversion or defibrillation pacing)
C
Comparator
Absence of external stimulation
O
Outcome
Trajectories of the waves and approximate limits of effective pacing periodssurrogate

This in-silico study provides insights into the dynamics of spiral waves on various surfaces and the effective pacing periods for low-voltage cardioversion.

Abstract

Spiral waves are widely spread throughout nature and have been an important research focus in recent decades. The spiral waves in active media (including cardiac tissue) tend to disappear when moving to the domain boundary. The study of the motion of the spiral waves on surfaces without boundaries is of scientific interest. In this paper, we simulated the dynamics of these waves on the following surfaces: a torus, a Mobius strip, and a cylinder. The tissue was simplistically modelled as an isotropic medium with the cell-level model of Aliev-Panfilov; the spiral waves were created using the S1S2 protocol. As a result, we obtained the trajectories of the waves in the absence and presence of external stimulation from a point electrode. Pacing of this kind, called low-voltage cardioversion or defibrillation, is used in clinic to stop paroxysms of dangerous heart rhythm disturbances, such as tachyarrhythmia, fibrillation, or torsade de pointes. An important parameter of the pacing is its period. We found the approximate limits of effective pacing periods and compared them with the results for a square. The spontaneous drift and annihilation of the paired spiral waves were observed.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kuklin et al. (2020) studied Cardiac arrhythmias. External stimulation from a point electrode vs. Absence of external stimulation / square surface was evaluated on Trajectories of the waves and limits of effective pacing periods. In-silico simulations of spiral waves on surfaces without boundaries (torus, Mobius strip, cylinder) identified approximate limits of effective pacing periods for low-voltage cardioversion.

synapsesocial.com/papers/6a11daba5a604c357c21abc6https://doi.org/10.1109/usbereit48449.2020.9117633
Ask AI
Helpful
Bookmark
Share
View Full Paper