Key result
High-frequency pacing successfully terminated spiral activity in a majority of cases by shifting rotating waves from their original sites via a paced-induced drift mechanism.
Why the study?
Does high-frequency pacing terminate spiral wave activity in monolayers of neonatal rat cardiomyocytes?
Does high-frequency pacing terminate spiral wave activity in monolayers of neonatal rat cardiomyocytes?
This study provides direct experimental evidence that high-frequency antitachycardia pacing terminates arrhythmias via paced-induced drift of rotating waves.
Supports paced-induced drift for spiral termination in vitro; leaves open clinical translation of high-frequency pacing.
For prevention of lethal arrhythmias, patients at risk receive implantable cardioverter-defibrillators, which use high-frequency antitachycardia pacing (ATP) to convert tachycardias to a normal rhythm. One of the suggested ATP mechanisms involves paced-induced drift of rotating waves followed by their collision with the boundary of excitable tissue. This study provides direct experimental evidence of this mechanism. In monolayers of neonatal rat cardiomyocytes in which rotating waves of activity were initiated by premature stimuli, we used the Ca(2+)-sensitive indicator fluo 4 to observe propagating wave patterns. The interaction of the spiral tip with a paced wave was then monitored at a high spatial resolution. In the course of the experiments, we observed spiral wave pinning to local heterogeneities within the myocyte layer. High-frequency pacing led, in a majority of cases, to successful termination of spiral activity. Our data show that 1) stable spiral waves in cardiac monolayers tend to be pinned to local heterogeneities or areas of altered conduction, 2) overdrive pacing can shift a rotating wave from its original site, and 3) the wave break, formed as a result of interaction between the spiral tip and a paced wave front, moves by a paced-induced drift mechanism to an area where it may become unstable or collide with a boundary. The data were complemented by numerical simulations, which was used to further analyze experimentally observed behavior.
No takes yet. Share an insight, caveat, or question.
Agladze et al. (2007) studied Arrhythmias. High-frequency pacing was evaluated on Termination of spiral activity and paced-induced drift of rotating waves. High-frequency pacing successfully terminated spiral activity in a majority of cases by shifting rotating waves from their original sites via a paced-induced drift mechanism.