Answers are grounded in this paper and cite their sources.
CCUS technology is currently the best practice for reducing CO 2 emissions, with pipeline transportation as the primary method for the long-distance, large-scale transport of captured CO 2 to storage sites. However, the two-phase flow often occurs during the transportation and storage of CO 2 . To accurately calculate the flow parameters of CO 2 two-phase flow, particularly the pressure drop gradient and liquid holdup, a new CO 2 two-fluid model incorporating droplet entrainment is developed. Additionally, a new numerical method is proposed to determine the fraction of droplet entrainment. The new model is validated with extensive experimental data from horizontal and vertical CO 2 pipelines with an error of ±17% for horizontal flows and around ±4% for vertical flows in pressure gradients prediction. The average prediction error for liquid holdup is less than ±8%. The effects of entrainment fraction, friction coefficient, pipeline inclination, liquid holdup, and flow pattern on the model's prediction performance are discussed. Overall, the new model significantly enhances the accuracy of predicting the pressure drop gradient, especially in the low liquid holdup and the annular flow pattern, highlighting the importance of considering droplet entrainment in CO 2 two-phase flow pipelines. The proposed model offers a more reliable solution for CO 2 two-phase flow and can be applied to other two-phase flows.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: