Key result
Aortic valve area calculated using flow acceleration velocity time integral in the proximal LVOT was 29.1% higher than calculations using distal LVOT measurements.
Why the study?
Spatial differences between flow and area measurement locations can make continuity equation-based AVA calculations inaccurate, prompting evaluation of the impact of proximal LVOT flow acceleration on AVA accuracy in aortic stenosis.
Does flow acceleration in the proximal LVOT impact the accuracy of aortic valve area calculation by continuity equation in patients with aortic stenosis?
Observational (n=46)
Does flow acceleration in the proximal LVOT impact the accuracy of aortic valve area calculation by continuity equation in patients with aortic stenosis?
Answers are grounded in this paper and cite their sources.
Measuring velocity in the proximal LVOT where flow acceleration occurs leads to significant overestimation of aortic valve area in patients with aortic stenosis.
Objective : Due to its circular shape, the area of the proximal left ventricular tract (PLVOT) adjacent to aortic valve can be derived from a single linear diameter. This is also the location of flow acceleration (FA) during systole, and pulse wave Doppler (PWD) sample volume in the PLVOT can lead to overestimation of velocity (V 1 ) and the aortic valve area (AVA). Therefore, it is recommended to derive V 1 from a region of laminar flow in the elliptical shaped distal LVOT (away from the annulus). Besides being inconsistent with the assumptions of continuity equation (CE), spatial difference in the location of flow and area measurement can result in inaccurate AVA calculation. We evaluated the impact of FA in the PLVOT on the accuracy of AVA by continuity equation (CE) in patients with aortic stenosis (AS). Methods : CE-based AVA calculations were performed in patients with AS once with PWD-derived velocity time integral (VTI) in the distal LVOT (VTI LVOT ) and then in the PLVOT to obtain a FA velocity profile (FA-VTI LVOT ) for each patient. A paired sample t -test ( P < 0.05) was conducted to compare the impact of FA-VTI LVOT and VTI LVOT on the calculation of AVA. Result : There were 46 patients in the study. There was a 30.3% increase in the peak FA-VTI LVOT as compared to the peak VTI LVOT and AVA obtained by FA-VTI LVOT was 29.1% higher than obtained by VTI LVOT . p] Conclusion : Accuracy of AVA can be significantly impacted by FA in the PLVOT. LVOT area should be measured with 3D imaging in the distal LVOT.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2019) conducted an observational in Aortic stenosis (n=46). AVA calculation using proximal LVOT flow acceleration (FA-VTI) vs. AVA calculation using distal LVOT velocity time integral (VTI) was evaluated on Aortic valve area (AVA) calculation. Aortic valve area calculated using flow acceleration velocity time integral in the proximal LVOT was 29.1% higher than calculations using distal LVOT measurements.