Key result
A mobile retained epicardial pacing wire caused hemopericardium 7 years after ventricular septal defect repair, which was accurately diagnosed using CT with multiplanar reconstruction and volume rendering.
Case Report (n=1)
No
Retained epicardial pacing wires can cause delayed, life-threatening complications such as hemopericardium, highlighting the importance of careful CT imaging review for accurate diagnosis.
Answers are grounded in this paper and cite their sources.
Retained epicardial wires merit consideration in delayed hemopericardium; case extends sparse literature but leaves management open.
BACKGROUND: Epicardial pacing wires (EPWs) are commonly employed for diagnosis and treatment of arrhythmia in the acute phase after cardiac surgery. Although rare, retained EPWs may cause mild-to-catastrophic complications. The present case demonstrates hemopericardium caused by a mobile retained EPW. METHODS: A 49-year-old woman presented to our emergency department with clinical signs of impending cardiac tamponade. She had undergone ventricular septal defect repair 7 years before this admission. An initial computed tomography (CT) scan revealed hemopericardium with suspicion of a possible intracardiac lesion. Review of the first and second CT scans, however, revealed a mobile retained EPW penetrating the pericardium in the first scan, which had moved out of the pericardium in the second scan. RESULTS: Because cardiac injury by the EPW was suspected, the patient was transferred to another medical center for further treatment. CONCLUSION: According to our experience with this case, diagnosis may be incorrect if CT is unable to obtain decisive images of the mobile EPW at the correct time. Multiplanar reconstruction and volume rendering can increase diagnostic accuracy. In conclusion, if hemopericardium is present without clear etiology in a patient with a retained EPW, a nearby mobile EPW may be the cause.
No takes yet. Share an insight, caveat, or question.
Hsu et al. (2016) conducted a case report in Hemopericardium caused by retained epicardial pacing wire (n=1). Computed tomography with multiplanar reconstruction and volume rendering was evaluated. A mobile retained epicardial pacing wire caused hemopericardium 7 years after ventricular septal defect repair, which was accurately diagnosed using CT with multiplanar reconstruction and volume rendering.